WTC dust sampling protocol, residence testing

Machine-extracted title · confidence 38%

Description of micro vacuuming and sampling locations for asbestos/lead testing.

NYC-WTC_000281769
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

WTC Indoor Air/Environments Monitoring - Sampling and Analytical Procedures For Background and Pilot Clean up Studies

Analytical Analytical Method Proposed Media Sampling Points Sampling Method Proposed Description Parameters This is a micro vacuuming method. Three co-located samples will Settled Dust Carpets, fabric furniture or Asbestos ASTM D 5755-95 ASTM D 5755-95 be collected from each location. Porous Soft drapery in areas of activity surfaces (living rooms, family rooms) This is a micro vacuuming method. Three co-located samples will Lead ASTM E 1973-99 SW-846 601 OB be collected from each location. Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe)

Lead HUD Appendix 13.1 Wipe Samples SW-846 601 OB Horizontal surfaces of Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290 Settled Dust tables or counters and bare Non-porous Wipe Samples ASTM 6661-01/SW-846 8270C floors, ceilings and walls in PAHs ASTM D 6661-01 Hard areas of activity (living Wipe Sample collected at one location per unit. No Formal Method (NIOSH 7500 Modified) surfaces Total Dust HUD Appendix 13.1" rooms, family rooms) Silica, calcite, NIOSH 7500 (XRD) HUD Appendix 13.1" Wipe Samples. All parameters will be collected on one wipe. gypsum MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300 Air pump operated at 10L/min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA Asbestos NIOSH 7400 wkgroup Practical Quantitation Limit (PQL) method. Air pump operated at 10L/min for 8 hours to achieve the COPC SW-846 601 OB Lead NIOSH 7300 wkgroup PQL Air pump operated at 2L/min for 8 hours. Pilot Clean-up study only SW-846 8270 (Analytical method with be PAHs NIOSH 5515 for worst case scenarios. modified to achieve the COPC wkgroup PQL Areas of known activity Indoor Air (living rooms, family rooms; Air pump operated at 25L/min for 35 hours. This modification is not Dioxins TO-9 (Modified for indoor air) a proven method. To be conducted during the Pilot Clean-up study SW-846 8290 only for worst case scenarios. Silica, calcite, Air pump operated at 2.5L/min for 8 hours to achieve the COPC NIOSH 7500 NIOSH 7500 (XRD) gypsum wkgroup PQL Assumed that it behaves the same as asbestos, samples will be MMVF NIOSH 7400 EMSL MSD.0300 combined with the asbestos sampling. Bulk samples will be collected from HVAC or AC window type unit PLM NYS 198.1 followed by Asbestos Bulk Sample filters, shaken into a plastic bag and transferred into the sample TEM NYS 198.4 container. (If the volume required is not sufficient for all analyses, the sample SW-846 601 OB Lead Bulk Sample HVAC systems and AC will be analyzed for asbestos only. o units (collection of bulk dust (If the volume required is not sufficient for all analyses, the sample PAHs Bulk Sample SW-846 8270 Bulk Dust sample from the unit air will be analyzed for asbestos only. H K filters) Background study (If the volume required is not sufficient for all analyses, the sample I only. Dioxins Bulk Sample SW-846 8290 to will be analyzed for asbestos only. 12 Silica, calcite, (If the volume required is not sufficient for all analyses, the sample O Bulk Sample NIOSH 7500 (XRD) gypsum will be analyzed for asbestos only. o (If the volume required is not sufficient for all analyses, the sample o MMVF Bulk Sample PLM NYS 198.1/EMSL MSD.0300 I will be analyzed for asbestos only. o o to NOTE: " Wipe samples for silica, calcite and gypsum will be collected using the HUD Appendix 13.1 method since no standardized method is available. Ui

cn

NYC-WTC_000281769

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000281769Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

WTC sampling plan and procedures

NYC-WTC_000277652

Plan describing micro vacuuming sampling method and target materials (asbestos, lead, etc.).

Similar indexed content

Compare copies and versions →