NYC-WTC_000186684
Draft GC/MS laboratory report for WTC Tedlar bag air samples collected on January 8, 2002.
1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗Draft GC/MS analysis for 01/08/02 at NYC708-713 Tedlar bag samples.
NYC-WTC_000280971
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
NO QC EVALUATION HAS BEEN PERFORMED, I DATA VALIDITY IS UNSUBSTANTIATED AND THE DATA SHOULD BE USED WITH DISCRETION •I
DRAFT GC/MS Results for 01/08/02 Tentatively Identified Compounds
File Name NYC708 NYC709 NYC710 Sample Location Instrument Blank Tedlar BagBlank Washing Tent Sample Number A07321 Sample Height Breathing Level Volume 250 mL 250 mL None None None
File Name NYC711 NYC713 NYC712 Sample Location Austin Tobin Plaza North Tower South Tower Sample Number A07324 A07322 A07323________ _____________ Sample Height Breathing Level Ground Level ; Ground Level Volume 250 mL 20mL_______________ _ 250 mL None Propylethylene 1900 ppby 3-Methylhexane 23 ppb„ 2-Pentene 260 ppbv Octamethyl-Cyclotetrasiloxane 27 ppb, Unknown 920 ppbv Isoprene 630 ppbv Cyclopentadiene 1600 ppbv Cyclopentene 510 ppbv 1-Hexene 1700 ppbv 2-Methylfuran 1200 ppbv Unknown 290 ppbv Unknown 830 ppbv Unknown 1400 ppbv 2-Pentanone 370 ppbv o H Unknown 280 ppbv I Unknown 430 ppbv NJ
S Unknown 860 ppbv o Octane 310 ppbv , 'f. o o Cyclopentanone 320 ppbv ,, > I S- *5.- o 2-Phenylprdpene 330 ppbv , , /’A
NJ
ffJ
<C'
NYC-WTC_000280971
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000186684
Draft GC/MS laboratory report for WTC Tedlar bag air samples collected on January 8, 2002.
1 shared topics · similarity 0.989
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280975
Draft GC/MS results for 01/07/02, NYC699- NYC704 samples.
1 shared topics · similarity 0.982
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281012
Draft GC/MS data for WTC air samples, Dec 27, 2001.
1 shared topics · similarity 0.977
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280881
Draft GC/MS results for NYC samples, 02/12/02.
1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000186616
Draft laboratory report showing GC/MS results for volatile organic compounds collected at the World Trade Center site on December 7, 2001.
1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281069
Draft GC/MS results for multiple NYC samples; data unvalidated.
1 shared topics · similarity 0.976
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281095
GC/MS results for Tedlar bag samples at NYC locations; no QC evaluation.
1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281032
Draft GC/MS results for NYC504- NYC509 with phenol detected; no QC evaluation.
1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000251974
Draft GC/MS results with Tedlar bag samples from WTC, 12/04/01.
1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280961
Draft GC/MS results for Tedlar bag air samples at WTC North/South Towers, Jan 11, 2002.
1 shared topics · similarity 0.974
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280993
Draft GC/MS results for 01/02/02 with phenol detection and sample locations.
1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281093
Draft GC/MS results for 12/02/01; compounds listed for NYC samples.
1 shared topics · similarity 0.973
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000186684
Draft GC/MS laboratory report for WTC Tedlar bag air samples collected on January 8, 2002.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280975
Draft GC/MS results for 01/07/02, NYC699- NYC704 samples.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281439
GC/MS results for WTC Tedlar bag air samples collected 03/17/02.
Similarity score 0.989 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281012
Draft GC/MS data for WTC air samples, Dec 27, 2001.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000281479
Draft GC/MS results for WTC bag air samples collected March 3, 2002.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000280881
Draft GC/MS results for NYC samples, 02/12/02.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000186684
Draft GC/MS laboratory report for WTC Tedlar bag air samples collected on January 8, 2002.
Similar indexed content
NYC-WTC_000280975
Draft GC/MS results for 01/07/02, NYC699- NYC704 samples.
Similar indexed content
NYC-WTC_000281012
Draft GC/MS data for WTC air samples, Dec 27, 2001.
Similar indexed content
NYC-WTC_000280881
Draft GC/MS results for NYC samples, 02/12/02.
Similar indexed content
NYC-WTC_000186616
Draft laboratory report showing GC/MS results for volatile organic compounds collected at the World Trade Center site on December 7, 2001.
Similar indexed content