NYC 9/11 Public Portal Document
yyjQ INDUSTRIAL HYGIENE ASBESTOS TEM RESULTS
Asbestos Air Sample Information Sheet
The air samples being collected at the World Trade Center site by ATC, Inc. under the
direction of Liberty Mutual are analyzed using two independent analytical methods as
described below.
Phase-Contrast Microscopy (PCM) Analysis
All asbestos samples collected by ATC for the purposes of worker exposure
assessment are analyzed by the PCM method. This is a fiber counting method in which
fibers are counted under an optical microscope. This is the method used to compare
results to the OSHA Permissible Exposure Limit (PEL) and to the Threshold Limit Value
(TLV) for asbestos. This method is quick and inexpensive and is the standard method
used for measuring worker exposure.
One limitation of the PCM method is that it cannot reliably distinguish between
asbestos fibers and other types of fibers, such as mineral wool, glass fibers, etc. So,
any asbestos air sample showing fiber counts in excess of 50% of the shift-adjusted
— 5;
occupational exposure limit (OEL) is also sent away for transmission electron
microscopy analysis.
Transmission Electron Microscopy (TEM)
Those air samples showing fiber counts in excess of 50% of the shift adjusted OEL by
PCM analysis are also analyzed using TEM analysis. This can be done on the very
same filter that was analyzed by PCM because only a portion of the filter is used for
each analysis.
TEM analysis provides information on the structure of fibers, so the TEM method can
distinguish between asbestos and other types of fibers.
TEM analysis is more time-consuming and expensive than PCM analysis and these are
two of the reasons why TEM analysis is not used as a standard method for measuring
worker exposure. Since it is not a standard method, there are no occupational
exposure limits to which to compare TEM results. Although TEM analysis can provide
information on fiber counts, in the occupational setting, TEM analysis is primarily used
to identify the types of fibers collected on a sample.
Air Sample Results
The attached information contains results of both PCM and TEM analyses. For each
sample, the upper line contains the PCM results. The PCM results have been reported
earlier as part of the "elevated exposure” reporting process. The lower line for each
sample contains the results of the TEM analysis. If asbestos was found by TEM, the
asbestos fiber count is reported.
If you have questions about this information, please call the Liberty Mutual industrial
hygienist on duty at 917-566-2576.
3/21/2002 2
CITY_21MC100_002961399
NYC-WTC_000280577
OCR can misread numbers and units. Confirm readings against the page image before using them.