NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Water analyses, World Trade Center, Feb 2002

Machine-extracted title · confidence 50%

MTBE levels for sump and dewatering discharges detailed; table of concentrations across samples.

NYC-WTC_000280263
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MORETRENCH AMERICAN CORPORATION www.moretrench.com

too Stickle Avenue March 6, 2002 P.O. Box 316 Rockaway, N.J. 07066 Tel: (973) 627-2100 Serial Letter 01-4906-63 Fax:l(973) 627-3950/627-6078 i VIA FACSIMILE (3 wfc) (212) 640-9207

Mr. Brian Peters Total# of Pages: 7 Bovis Lend Lease LMB, Inc. 52 Chambers Street New York, NY 10007

RE: WTC - Dewatering - Contract No. 20020004649 MTA Job 01-4906 Water Analyses

Dear Brian:

Attached find complete results of the analysis of the water samples taken from the WTC site on February 22. 2002. It is apparent from reviewing the data that the samples have been mislabeled. Two samples are taken for analysis each time. All of the test results for the 2/22/02 sampleJabeled “well discharge" are consistent with the previous test results for the “sump discharge" and the 2/22/02 sample labeled “sump discharge” is consistent with previous results for the "well discharge." We have made changes to our sampling procedures to assure that this does not happen in the future. We apologize for this mistake.

MTBE levels for the sump discharge (South Projection) and dewatering well discharge (Main Discharge) should read 48 ppb and 6 ppb, respectively.

We are also forwarding a copy of the table which, tracks MTBE concentration for all of the water sample testing which has been performed on the site. We have adjusted the readings for February 22'’'* to reflect the obvious mix-up.in the sampling.

Very truly yours, MORETRENCH AMERICAN CORPORATION

7^'77.'■ <^<5^ «€ President

cc; Billy Klingler, MTA

MORETRENCH SERVICES....

• BORED PILES & SHAFTS • CUTOFF/CONTAINMENT WALLS • DEWATERING • GROUND FREEZING • GROUNDWATER REMEDIATION • INDUSTRIAL ESTRASTRUCTURE • LANDFILL GAS/LEACHATE SYSTEMS • SOIL MODIFICATION/SOILSTABILIZATION

TOO Ig] Nvoiaawv HONaaiaaow ogee zes cze rva og-TT ?ooe/zo/eo CITY_21MC100_002947742

NYC-WTC_000280263

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000280263Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →