7 INDUSTRIAL HYGIENE ELEVATED EXPOSURE NOTICE

Date: 03/05/2002

To: Ray Master

CC: DDC- Bob Adams LMIG- John Rabovsky ATC- Mike Donovan LMIG- IH File

From: Mike Ramsey

RE: Elevated Exposures

Ray,

Attached are Elevated Air Sample Result Notifications for samples analyzed on 3/1/02 and 3/4/02. Elevated exposures are defined as above 50 % of the shift adjusted time weighted average (TWA) Occupational Exposure Limit (OEL) for the purpose of this notification. These are provided to you for distribution. You indicated that you will provide these to the contractor involved. The contractors affected were;

• EROC • Nicholson • Safeway Environmental • Tully

The following is a summary of the elevated exposure information that is attached:

• A quartz concentration of 15000% and a respirable dust concentration of 204% of the shift adjusted OEL on a Brokk operator in WTC 6, level B5. To my knowledge, this is the highest quartz exposure found so far on the site and it exceeds the protection of even full face-piece respirators, which have a nominal fit factor of 50.

• A quartz concentration of 117% of the shift adjusted OEL on a worker cleaning up debris at the B1 level of WTC 6.

• A quartz concentration of 117% of the shift adjusted OEL on a driver (Bobcat?) in WTC 6, LvI B2.

• A quartz concentration of 958% of the shift adjusted OEL on a driver (Bobcat?) in WTC 6, LvI B2.

If future samples of Brokk operators indicate that the one sample result listed above is not an “outlier” and exposure can’t be reduced by other means, upgrading the respiratory protection beyond full face-piece respirators will be necessary for this job. The Brokk machines are equipped with remote control boxes and one obvious control is to assure that workers stand as far away from the breaker as possible. When

3/5/2002 I

CITY_21MC100_003128599

NYC-WTC_000280022

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000280022Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →