Oxides of .Nitroge.n/ Sulfur: Samnlmg or. urappler operators on the rubble pile, and on employees irinning truck wash stations revealed trace levels of nitric oxide and nitrogen dioxide. iO; personal and area results were found to be below OSKA limits.

Metals: OSHA has taken 653 air samples to monitor worker exposures to dusts, fines, o.xides, and other compounds of metals such as antimony, bery/llium. chuomium. coalt, copper, iron, lead, manganese, molybdenum, nickel, vanadium, zinc, cadmium, magnesium, arsenic, and mercury. Results from these samples are generally we" below the applicable OSHA limits. However, torch cutting and burning structural steel at the rubble aile have resulted in instances of overexposures as follows: coppu (10); iron oxide (21); lead (12); and cadmium (2). Accordingly, OSFIA is recomit.ending that workers engaged in these operations wear appropnate respiratory protec'jon.

Ionizing Radiation: A survey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation with particular attention to alpha radiation. Preliminary results show no elevated levels.

Dioxins: OSHA has taken samples for dioxin and these samples were analyzed byEPA. One initial sample, representing e.xposure directly on the pile, showed elevated levels of dio.xins w'hen compared to ambient background levels. This t'alue was comparable to the levels found by EPA sampling. The dioxins at this location are being emitted from the on-going rubble fire. .Additional sampling was conducted around the perimeter of the pile and revealed levels that were considerably lower than those on the rubble pile. Dioxins are considered collectively as suspect human carcinoge.ns. OSH.A does not have a worker standard for dio.xins. OSH.A is coordinating with EPA, and the Salt Lake City Analytical Laboratory to fully assess the nsk posed by the elevated levels of dioxins. Polynuclear Aromatic Hydrocarbons OSHA has taken 132 samples. Tae majority' of the samples have not shown the presence of benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons: anthracene, acridine, pyrene, chrysene and phenanthrene. Sample results to date have identified seven samples which reached ore.xceeded OSHA’s coal tar pitch volatile PEL of O.dmg.W . These personal samples were taken on the pile on iron workers and grappler operators. OSH.\ continues to strongly recommend the use of respiratory protection when working on the rubble pile. Freon R-Z:, Hydrogen Fluoride & Phosgene: OSHAhas taken 105 samples for Freon R-22 (chlorodiflouromethane). The majority of sample results received to December 17* reveal non-detcctable airborne levels. During operations involving Freon removal from the au.xiliary chiller that started on 12/5/01, direct reading instrument revealed readings ranging from 1OO ppm to one peak near a leaky' valve of 500 ppm. SCB.-\ tanks were and are being worn by workers, and masks are to be worn only when direct reading instruments reveal 850 ppm Freon and or less than 20.4% O.xygen. OSHA does not have an e.xposure limit for Freon R-22. (The NIOSHREL for Freon IS lOOOppm..) In response to information about exposure to the decomposition by-products of Freon R-22 used in the air conditioning systems ofWTC towers, sampling for hydrofluoric acid (HF) had been conducted. Results for HF revealed non-detectable levels. Sample results for phosgene to date show non- detectable levels.

Page 2 of 2

CITY_21MC100_003144962

NYC-WTC_000278732

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278732Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →