NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Lab report, W.T.C. paving bulk density, May 2002

Machine-extracted title · confidence 42%

Bulk specific gravity of compacted mixture, cores, May 2002.

NYC-WTC_000278525–000278526
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

MUNICIPAL TESTING LABORATORY, INU. 102 NEW SOUTH ROAD, HICKSVILLE NEW YORK, 11801 (516) 938-7120,-FAX (516) 938-5107 www.municipaltestinglab.com email: municipal @ iTiunicipaltestinglab.com A FULL SERVICE LABORATORY AND ENGINEERING CONSULTANT; STEEL. CONCRETE, SOILS, ASPHALT & ALL BUILDING MATERIALS

LABORATORY REPORT CLIENT: LIRO____________ DATE-PLACED: 05/06/02 PROJECT: W.T.C. Paving ’ DATE-CORED: 05/09/02 CALCULATIONS BY: M.Mathew TESTED: 05/13/02 REPORT No. 9223 SPEC: NYCDDC Page 1 of 2 BULK SPECIFIC GRAVITY OF COMPACTED MIXTURE Bi^aASTM 0^2726 WEIGHT - GRAMS CORE IN IN SAT-SUR. VOLUME SPECIFIC Thick- NO. AIR WATER DRY CU.CM. GRAVITY Gmb ness(mm) D E E1 (E1-E)=F D/F=G 51 H1 933.7 555.0 936.6 381.6 2.447 51 H2 901.7 518.6 906.4 387.8 2.325 19 H3 402.5 242.4 403.1 160.7 2.505 44 H4 733.3 432.6 738.7 306.1 2.396 44 H5 811.8 484.6 812.9 328.3 2.473 38 H6 550.8 322.8 555 232.2 2.372 38 H7 641.3 375.2 647.3 272.1 2.357 38 H8 657.4 387.0 660.3 273.3 2.405

PAVEMENT DENSITY CALCULATIONS CORE BULK SPEC. SPECIFIC GRAVITY PERCENT GRAVITY DESIGN MIX VALUE COMPACTION CORE ASTM D-2726 (PLANT SUPPLIED) (Gmb/Gmm) NO. Gmb Gmm x100 HI 2.447 NA NA H2 2.325 NA NA H3 2,505 NA NA H4 2.396 NA NA H5 2.473 NA NA H6 2.372 NA NA H7 2^ NA NA H8 2.405 NA NA PERCENT ASPHALT CONTENT - 7.2% (TAKEN FROM CORE #PI)

CITY_21MC100_004662579 NYC-WTC_000278525

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278525Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →