NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

PCM fiber lab report, Oct 1998

Machine-extracted title · confidence 21%

Microscopy (PCM) fiber results with sample collected and fiber measurements.

NYC-WTC_000278039
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

< (

SciLabJob#: 98-10-5219 Client Name: Applied Technology Services, Inc. Phase Contrast Microscopy (PCM) Fiber Results A98113: Rtcrman Hall, lOlh To 13th FlrTDurings Flow Ajr Fiber .t^ibers SciLab Client Rale Dutaiion Filleted Density Cone. Fields Fibers TWA Sample # Sample Location Collected (liiers/min.) (mtn.) (liters) (Ftbers/rnm ) (Fibers/cc)

01 inside KL1OO298-OI 10/2/98 10 120 1200 100 15 19 11 0 006 12lh Fir., Conference Rn>. 1208/Souib Comer/ISWA 02 ouisKie KL100298-02 10/2/98 10 120 1200 100 14 17.83 0 006 12lh Fir., Conference Rm. 1251, North' Comer/OSWA 03 inside KL 100298-03 10/2/98 10 120 1200 NA W A. Opposite Rm 1251. South Sidc/ISWA Footnotes: 2

04 DuUide KL 100298-04 10/2/98 10 120 1200 100 9 I 1 46 0.004 W A. Opposite Rm 1251. South Sidc/OSWA 05 inside KL 100298-05 10/2/98 10 120 1200 NA WA Behind Rm 1248, South SidenSWA Footnotes: 2 06 outside KL 100298-06 10/2/98 10 120 1200 NA WA Behind Rin 1248, South Sidc/OSWA Foatootes: 2 07 KLIOO298.O7 10/2/98 0 0 0 lOO o.s 0.64 Field Blank Footnotes: J OS KLI00298-08 10/2/98 0 0 0 100 0.5 0.64 Field Blank Footnotes: / Reporting Notes: (I) Fibees/ce cannot be calculated (or samples (or blanks) with no air volume. (2) Analyst was unabUe to quantify fiber coticentrauon because of overloading of paniculate material on (he filter. Analyzed' bye Larisa Srybnaya Itl_____ -“^6^ /________ ; Dale Analyzed: 10/3/98 Samplea analyzed by NIOSH 7400(A) METHOD, Issue #2,'^13/94; Limit of Detection = 5.5 fibers pet 100 fields or 7 fiben / mni2; This report relates ONLY to the sample analysis expressed as (iben/sq uun of filler area; ND = no fibers observed; NA = Not Analyzed; Walton ■ Beckett gradicule field area 0 00783 inm2. Duration in minutes. TWA = 8tlr TWA calculation assumes zero exposure for remainder of 8 hour period not sampled; Upper 95% Confidence Limit (Employer's Compliance Test) - Calculated as a one sided UCL to determine 95% certainly ol compliance with the 0.01 Fiber/cc standard; Estimated relative standard deviation: Intralab Sr « 0.270, Interlab Sr w 0.450. El-AP Fl 1480 O

to a —t S o P T3 o o G) I UI o o co

o to to

NYC-WTC_000278039

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000278039Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →