PCM fiber results, 98-08-6653

Machine-extracted title · confidence 36%

SciLab PCM fiber results with 7th Floor air sampling data.

NYC-WTC_000277995–000277996
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

( ( X

SciJL^ Job#: 98.08-6653 Client Name: Applied Technology Services, Inc. Phase Contrast Microscopy fPCM) Fiber Results A98113; 7th Floor; Preparation Flow Air Fiber Fibers SciLab Client Date Rate Duration Filtered Densify Cone. Reids Fibers TWA Sample # Sample # / Location Collected (Hters/min.) (min.) (liters) (Fibers/mm ) (Fibets/cc)

16 34081898-16 8/18/98 5 310 1550 100 0.5 0.64 < 0.002 7-Tent #52-IWA 17 34081898-17 8/18/98 5 310 1550 100 2 2.55 < 0.002 7-Tent #53-IWA 18 34081898-18 8/18/98 5 310 1550 100 0.5 0.64 < 0.002 7-Tent #54-IWA 19 34081898-19 8/18/98 5 310 1550 100 2 2.55 < 0.002 7-Tent #55-IWA 20 34081898-20 8/18/98 5 310 1550 100 1 1.27 < 0.002 7-Tent #56-IWA 21 34081898-21 8/18/98 5 310 1550 100 4 5.10 < 0.002 7-Tent #57-IWA 22 34081898-22 8/18/98 5 310 1550 100 2 2.55 < 0.002 7-Tent #58-IWA 23 34081898-23 8/18/98 0 0 0 100 0.5 0.64 Field Blank Footnotes: / 24 34081898-24 8/18/98 0 0 0 100 0.5 0.64 Field Blank Footnotes: / Reporting Notes: (1) Fibers/cc cannot be calculatet for samploi (or blanks) with no air (2) Analyst was unable to quanti! fiber ration wamading of particulate material on the filter. Analyzed by: Anthony Hinton J Analyzed: 8/19/98 Samples analyzed by NIOSH 74K OMI Limit of Detection = 5.5 fibers per 100 fields or 7 fibers / mm2; This report relates ONLY to the sample analysis expressed o ' as fibers/sq mm of filter area; ND s no fibers o NA = Not Analyzed; Walton - Beckett gradicule field area 0.00785 mm2; Duration in minutes; TWA = 8Hr TWA calculation assumes zero exposure for remainder of 8 hour period not sampled; Upper 9S% Confidence Limit (Employer's Compliance Test) - Calculated as a one sided UCL to determine 95% certainty of I compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr = 0.270, Interlab Sr = 0.450. ELAF #11480

o o I o o co

o o Ui

NYC-WTC_000277996

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277996Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →