SciLab PCM fiber results, 97-5457

Machine-extracted title · confidence 32%

SciLab PCM fiber results for air samples and fiber counts, 1997 finals.

NYC-WTC_000277971
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

< ( ( SciLab Job#; 10-97-5457 Client Name: Applied Technology Services,. Inc. Phase Contrast Microscopy (PCM) Fiber Results A97195: FINALS Air Fiber Fibers SciLab Client Dale Duration Rate , . . Filtered Reids Fibers Density Cone. TWA Sample # Sample # / Location Collected Giters/ntin.) (liters) (Fibers/mm * ) (Fibers/cc) 01 29100997-01 10/9/97 15 «0 1200 100 2 2.55 < 0,002 FIN BaietneW-in Computer Office/ISWA 02 29100997-02 110/9/97 IS 80 1200 100 4.5 5.73 < 0,002 FIN-Basetnenl-io Computer Office/ISWA 03 29100997-03 10/9/97 15 80 1200 too 0,5 0.64 < 0 002 FIN-Basemenl-tn Corridor/ISWA 04 29100997-04 10/9/97 15 80 1200 100 0.5 0.64 < 0.002 FIN-Basement-Entrance w Tcnt/OSWA 05 29100997-05 10/9/97 15 80 1200 100 0.5 0.64 < 0.002 FIN-Basement-in Conidor/OSWA 06 29100997-06 10/9/97 15 80 1200 100 0.5 0.64 < 0.002 FlN-Basemcnt-in Supply Roam/OSWA 07 29100997-07 10/9/97 0 0 0 100 0.5 0.64 Blank Fooiiioles: /

08 29100997-08 10/9/97 0 0 0 100 0.5 0.64 Blank Footnotes; I Reporting Notes: 1 J > jf Cl) Fibers/cc cannot be calailated for satwiM wi Analyzed by: Anthony T. Hinton /^V^r *** A"***®***: 10/9/97 Samples analyzed by NIOSH 740CXA) METHOD, JmUc #2, 8/15/9% Limit of Detection = 5.5 fibers per lOO fields or 7 fibers / tnm2; Tliis report relates ONLY to the sample analysis expj as fibers/sq mra of filter area; ND = no fibers observed; NA = No/Analyzed; Walton - Beckett gradicule field area 0.00785 mm2; Duration in minutes; TWA = SHrTWA calculation assun zero exposure for remainder of 8 hour period not sampled; Uppctf95% Confidence Limit (Employet’s Compliance Test) - Calctilaied as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard: Esdniated relative standard deviation; Intralah Sr = 0 270, inicriab St = 0.450. o H

K)

S o o o o P I ■U o

it.

ro co

NYC-WTC_000277971

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277971Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →