PCM fiber results with flow, liters, and fiber counts for samples in DURING area.

NYC-WTC_000277951
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

( (

Clienl Name: Applied Technology Services, Inc. Phase Contrast Microscopy (PCM) Fiber Results A97195; F: Herman Hill, 30 W, Broadway, DURING Flow /kir Fiber Fibers .ciLab Client Date Duration Rale Filtered Fields Fibers Density Cone. TWA iniplc # Sarapie #,/ Location Colleclsd (min.) (liters/min.) (liters) (Fibers/tnm ) (Fibers/cc) 01 YK-Ol 9/2/97 3 360 1800 100 5 6.37 < 0.001 Ist Floor Pers Decon, By Clean Room 02 YK-02 9/2/97 3 360 1800 100 S 10.19 0,002 2iid Floor, Corridor N. Side 03 YK-03 9/2/97 3 360 1800 100 13 16.56 0.004 2nd Floor, Corridor W. Side 04 YK-04 9/2/97 3 360 1800 too 2 2.55 < O.OOI 2nd Floor, Corridor E Side 05 YK-C3 9/2/97 3 360 1800 100 8 10.19 0.002 2nd Floor, Corridor S. Side 06 YK-06 9/2/97 0 0 0 100 0.5 0.64 Field Blank Fonlnotes: I 07 YK-07 9/2/97 0 0 0 100 0.5 0.64 Field Blank . Footnotes:' / Reporting Notes: fl / , (1) Fibers/cc cannot be calculated fot^mpl^ydx^lanks) wii ail Analyzed by; Anthony T. Hinton J Analyzed: 9/3/97 ELAP # 11480. Samples analyzed by NIOSH 74O<HA4 MBTlIOp^^suc ’I5/9X; Limit of Oetcclion = 5.5 fibers per 100 fields or 7 fibers / mm2; This report relates ONLY to the sample analysis expressed as fibers/sq itun of filter area; ND = no fibers red; NA = Nd Analyzed; Walton - Beckett gradicule field area 0.00785 mm2; Duration in mioules; TWA = 811i TWA calculation assumes zero exposure for remainder of 8 hour period not sampled; Dppef 95% Confidence Limit (Employer's Compliance Test) - Calculated as a one sided UCL to determine 95% certainly of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation; Intralab Sr = 0.270, Interlab Sr = 0.450. Phase Contrast Microscope; Olympus, .Model CH-2.

o H

to I—. S O o o I o

us. o o

NYC-WTC_000277951

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277951Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →