SciLabJob#: 202013270 Client Name: Environmental Health Investigations, tnc. Table! 5I Summary of Bulk Asbestos Analysis Results & 0224-0572; Bovis Lend; 75 Park Place, Mechanical Rooms At 9th, Sth, & 7th Eoors G

SciLab Client HG Sample Heat Add Insoluble S Sample Sample* Area Weight Sensitive Soluble Non-Asbestos Asbestos by Asbestos by # Location (gram) Organic % laorganic % Inorganic % PLMflOS TEM 01 75P-O12502-36 NVA NA In Mechanical Room Inside Duct On The 9t!i Floor (Front Access) 02 75P-Oi2502-37 NVA NA In Mechanical Room Inside Dust On The 9th Floor (Rear Access) rr 03 75P4)12502-38 z NVA NA In Mechanical Room Inside Duct On The Sth Poor (Front Access) 04 75P-012502-39 NVA NA In Mechanical Room Inside Duct On The Sth Poor (Rear Access) £00 05 75P-O125O2-4O NVA NA UI In Mechanical Room Inside Duct On The 7th Poor (Front Access) 06 75P-0J25O2-41 NVA NA In Mechanical Room Inside Duct On The 7lh Poor (Rear Access) 07 75P-012502-42 NVA NA In Mechanical Room Inside Duct On The 6th Poor (Front Access) OS 75P-012502-43 NVA NA In Mechanical Room Inside Duct On The 6lh Floor (Rear Access)

Analyzed by; Bella Chemi s. Dale Analyzed: 1/27/02 hj •NAlVNSDx no asbeslm detected; NAsootan^yzed; MAH'S = not analyzed/pmitive dor. PtMadkAsbeMo8AiialysiibyBPA(i0tWM4-82-OX>per4OCRR763(NVLAPUb»20054«4J)andELAPPLM Aralyif;^ Pratocol 198.1 for New York samples (NYSDOH ELAP Lab* 11480); ELAP TEM AoalysaFretoooI 198.4 tor cejative NY NOB satnplej; Note: PLM is not oonsislenlly reliable io detecdog asbestos io floor coverings and similar aan-fnable organically bound nutoials. TEM is currently (he only method that can be used to detemine if this material can be cansidered or neated at »oo ajbertas<anUuiing in New York Stale (also see EPA Advisory for floor die. FR 39,146,38970.8/1/94). Natjonal Imbtutt of Sandards and Technology Aceredilaboo tequiremeott mandate dial llus report Rinst uol be reproduced eacepl in full wilhoiit die approval of the laboratory. ThisPLM report relates ONLY to the items tested. 5^ AIHA# 102843: VTCert* ALOIdtBJ NVA=No Visible Asbejlos

Reviewed By:, T O

a

NYC-WTC_000277803

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277803Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000277743

Table I: bulk asbestos analysis results for 75 Park Place (6th-9th floors).

Similar indexed content

Compare copies and versions →