NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Bulk asbestos results, 75 Park Place, 9th-7th floors

Machine-extracted title · confidence 42%

Summary of asbestos results across samples from 75 Park Place, 9th, 8th, and 7th floors.

NYC-WTC_000277783–000277784
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

SciLabJob#: 202013270 Client Name: Environmental Health Investigations, Inc. Table! 3I h Summary of Bulk Asbestos Analysis Results 0224-0572; Bovis Lend; 75 Park Place, Mechanical Rooms At 9th, Sth, & 7th Floors g SdLab CUeot HG Sample Heat Add Insoluble 8 Sample Sample# Ana Wei^t Sensitive Soluble Non-Asbestos Asbestos by Asbestos by # Location (gran) Organic % laorganic % Inorganic % PLNVDS TEM 01 75P-012502-36 NVA NA In Mechanical Room Inside Duct On The 9th Roor (Front Access) 02 75P-OJ 2502-37 NVA NA In Mechanical Room Inside Dust On The 9(h Floor (Rear Access) 5^ 03 75P-012502-3g NVA NA 3 In Mechanical Room Inside Duct On The Sth Floor (Front Access) 04 75P-012502-39 NVA NA tn Mechanical Room Inside Duct On The Sth Floor (Rear Access) 5cc 05 75P-012502-40 NVA NA a In Mechanical Room Inside Duct On The 7th Floor (Front Access) 06 75P-0I25O2-41 NVA NA In Mechanical Room Inside Duct On The 7th Floor (Rear Access) 07 75P-012502-42 NVA NA Io Mechanical Room Inside Duct On The 6th Floor (Front Access) OS 75P-012502^3 NVA NA In Mechanical Room Inside Duct On The 6th Floor (Rear Access)

Analyzed by: Bella Cbeniis. Sgtz.1^ Dale Analyied 1/27/02 n. •NAD/NSD = no asbestm detected. NAsooian^yied; MAH’S =noi»n»iyiod/pmidve stop; PLMBidkAst)atas AiiitysiibyE]>A«KVM4.82-0X>pcr4OCHt763{NVLAPUt)lt200S4«4)aDdELAPPLM Anaty:};^ Frotocol IDS. 1 fe New York sunploCNYSDOH ELAP Lab* IMSO); ELAP TEM Analysis Frotocol 1,8-4 lor negative NY NOB snmples: Note: PLM is not oaosiiteally reliable in detecBog asbestos io floor coverings g. and similai nan-friable organically bound nulerials. TEM is currently de only mcdiod that can be used to detennine if this material can be caniideied or treated as non asbestDs^cnlaining in New York State (also see EPA Advisory for floor tile, FR39.146,3M70,8/1/94). National Inslilutt of Standards and Technology Aocrtdilatioo requiremna mandate that litis report most uol be leproduoed except in full withont Ok approval of Che laboratory. This PLM report relates ONLY in the items tested. AIHA* 1028*3; VTCerti AL0I6C55 NVA=No Visible Asbeaus

Reviewed By:. T G r<

NYC-WTC_000277783

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277783Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000277743

Table I: bulk asbestos analysis results for 75 Park Place (6th-9th floors).

Similar indexed content

Compare copies and versions →