NYC 9/11 Public Portal Document
WTC Indoor Air/Environments Monitoring - Sampling and Analytical Procedures For Background and Pilot Clean up Studies
Analytical
Media Sampling Points Sampling Method Proposed Description Analytical Method Proposed
Parameters
This is a micro ; xjuniing method. Three collocated samples will
Settled Dust Carpets, fabric furniture or Asbestos ASTM D 5755-95 ASTM D 5755-95
be collected from each location.
Porous Soft drapery in areas of activity
surfaces (living rooms, family rooms) This is a micro v;.icuuming method. Three collocated samples will
Lead ASTM E 1973-99 SW-846 601 OB
bo collected from each location.
Asbestos ASTM D 6480-99 Wipe Samples ASTM D 6480-99 (wipe)
Lead HUD Appendix 13.1 Wipe Samples SW-846 6010B
Horizontal surfaces of
Settled Dust Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290
tables or counters and bare
Non-porous
floors, ceilings and walls in PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C
Hard
areas of activity (living
surfaces Total Dust ■ HUD Appendix 13.1 Wipe Sample collected at one location per unit. No Formal Method (NIOSH 7500 Modified)
rooms, family rooms)
Silica, calcite,
HUD Appendix 13.1’* Wipe Samples. All parameters will be collected on one wipe. NIOSH 7500 (XRD)
gypsum
MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300
Air pump operated at lOL'min for 8 hours to achieve the COPC PCM NIOSH 7400 followed by TEM AHERA
Asbestos NIOSH 7400
wkgroup detection limit method.
Air pump operated at 10L/min for 8 hours to achieve the COPC
Lead NIOSH 7300 SW-846 601 OB
wkgroup detection limit
SW-846 *327d (Analytical method with be
Air pump operated at 2L/min for 8 hours. Pilot Clean-up study only
PAHs NIOSH 5515 modified to achieve the COPC wkgroup detection
for worst case scenarios.
limit
Areas of known activity
Indoor Air
(living rooms, family rooms) Air pump operated at 25L/min for 35 hours. This modification is not
Dioxins TO-9 (Modified for indoor air) a proven method. To be conducted during the Pilot Clean-up study SW-846 8290
only for worst case scenarios.
Silica, calcite, Air pump operated at 2.5L/min for 8 hours to achieve the COPC
NIOSH 7500 NIOSH 7500 (XRD)
gypsum wkgroup detection limits
Assumed that it behaves the sarne as asbestos, samples will be
MMVF NIOSH 7400 EMSL MSD.0300
combined with the asbestos sampling.
Bulk samples will be collected from HVAC or AC window type unit
PLM NYS .198.1 followed by
Asbestos Bulk Sample filters, shaken into a plastic bag and transferred into the sample
TEM NYS 198.4
o container.
H (If the volume required is not attainable for all analysis, the sample
Lead Bulk Sample SW-846 601 OB
K will be analyzed for asbestos only.
I HVAC systems and AC
to (If the volume required is not attainable for all analysis, the sample
units (collection of bulk dust PAHs Bulk Sample SW-846 8270
sample from the unit air will be analyzed for asbestos only.
Bulk Dust
filters). Background (If the volume required is not attainable for all analysis, the sample
o Dioxins Bulk Sample SW-846 8290
o study only. will be analyzed for asbestos only.
I (If the volume required is not attainable for all analysis, the sample
o Silica, calcite, NIOSH 7500 (XRD)
o Bulk Sample
gypsum will be analyzed for asbestos only.
co (if the volume required is not attainable for all analysis, the sample
to Bulk Sample PLM NYS 198.1/EMSL MSD.0300
o MMVF will be analyzed for asbestos only.
o naiHte and ovosum will be collected using the HUD Appendix 13.1 method since no standardized method is available.
DRAFT
NYC-WTC_000277654
OCR can misread numbers and units. Confirm readings against the page image before using them.