Summary of analytical results, 100 [name], Sep 2001

Machine-extracted title · confidence 40%

TEM fiber results for ambient/ lobby air at 100 [name] site.

NYC-WTC_000277297–000277304
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

JLC ENVIRONMENTAL CONSULTANTS. INC. 200 Park Avenue South, Suite 1001, New York, New York 10003 Phone: (212) 420-3119 Fax: (212) 420-6092 Project No.: 01-2094 Insignia Residential Group, Inc. ELAP Lsfc Code; 11029 Analyte; FIBERS 675 Third Avenue NIC;P Code: 100273 Date Received: 9/20/01 New York, NY 10017 NVLAP Lab Code: 101953 Date Analyzed: 9/20/01 Batch #: i0109A643 SUMMARY OF ANALYTICAL RESULTS Si,e: ! 100 John Street, New York, NY

SAMPLE# COLLECTED DESCRIPTION / LOCATION TIMEImin) VOLUME(I) FIB/FIELD RESULTS(f/cc) LAB#

007 Ambient/ 3rd Floor/ Hallway 60 923 5/100 0.003<LOD 1H-September A 6324

008 Ambient/ Apartment #3302/ Living Room Area 60 923 4/100 0.002<LOD 19-September A 6325

009 Ambient/ 32nd Floor/ Hallway 60 923 2/100 0.001 <LOD 19-September A 6326

010 Ambient/ Apartment #3201/ Foyer Area 60 923 5/100 0.003<LOD 19-September A 6327

oil Ambient/ 31st Floor/ Hallway 60 923 5/100 0.003<LOD 19-September A 6328

012 Ambient/ Apartment #3102/ Foyer Area 60 923 6/100 0.003 19-September A 6329

Sample Analysis by: <LOD = Less than limit of detection which is 5.5 Fibers/100 Fields Positive Phase Contrast Microscopy (PCM) VOID1 = H.C.P. (High Concentration of Particles) VOID2 = Overloaded Method of Sample Preparation and Analysis: All samples analyzed in accordance with the NIOSH 7400 Method using "A" Counting Rules. Issue 2. August 1994 Instrumentation: Al wanner Olympus PCM Model BH-2 with Walton-Beckett Graticule (lOOum field diameter). Laboratory Director Report Date; Sefrtember 20, 2001 JLC is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400, Among other limitations, this method gives only an index of airborne fibers and provides only an estimate of asbestos concentration. Any and all claims arising out of JLC's analysis of these samples are limited in recovery to the cost of analyzing samples. JLC accepts no other liability and the client agrees to seek no costs beyond the above. Page 2 of 8

CITY_21MC100_009018634

NYC-WTC_000277298

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000277298Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →