Final Report: Investigation of Exposures to Dust, WTC Manhattan

Machine-extracted title · confidence 32%

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

NYC-WTC_000276826–000276962
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Table 10 Summary of Airborne Fibers at Locations Where Only Synthetic Vitreous Fibers (SVF) Were Detected in Settled Surface Dust

Outdoor Areas in Lower Manhattan Building Area Asbestos in Dust SVF in Dust Aggressive Fibers in Air (PLM or TEM)“ (PLM)" Sampling' (PCM)** 18 Outdoor 30% No <0.001 f'/cc 24 Outdoor ND* 55% No 0.002 f/cc 28 Outdoor nF 15% No <0.001 £/cc

Common Areas in Lower Manhattan Building Area Asbestos in Dust SVF in Dust Aggressive Fibers in Air (PLM or TEM)“ (PLM)’’ Sampling' (PCM)**

2 Common ND' 27% No 0.005 f/cc' 7 Common nF 5% No 0.001 f/cc 14 Common nF 5% No 0.003 f/cc Common W 5% No <0.001 f/cc 26 Common nF 5% No 0.004 Ecc' 28 Common nF 10% No 0.001 Ecc

Residential Units in Lower Manhattan Building Area Asbestos in Dust SVF in Dust Aggressive Fibers in Air (PLM or TEM)’ (PLM)’’ Sampling' (PCM)"

1 Residence 1 nF 20% No 0.006 Ecc' 1 Residence 2 nF 20% Yes <0.001 Ecc Residence 1 nF 25% No <0.001 f/cc 2 Residence 2 nF 20% Yes 0.002 f/cc 6 Residence 1 nF 15% Yes <0.001 f/cc 6 Residence 2 nF 15% Yes <0.001 fZcc 7 Residence 2 nF 5% No <0.001 f/cc 10 Residence 1 nF 15% Yes 0.001 f/cc To Residence 2 nF 10% Yes 0.001 Ecc 12 Residence 1 ND* 5% No 0.001 Ecc 12 Residence 2 5% Ym <0.001 Ecc 13 Residence 1 ND' 10% Yes 0.003 f/cc 15 Residence 2 nF 5% Yes <0.001 f/cc IS Residence 1 ND' 30% No 0.002 Ecc 18 Residence 2 nF 35% No 0.002 f/cc 24 Residence 2 ND' 10% No 0.005 f/cc' Residence 1 ND' 5% No <0.001 Ecc E2?'’ Residence 2 niY 10% No <0.001 f/cc a. Value shown is highest of the reported polarized light microscopy (PLM) and transmission electron microscopy (TEM) results for this area. b. SVF = synthetic vitreous Fibers. Measured by PLM analysis. c. Aggressive sampling refers to a technique used in some residential units where the vacuum exhaust (used for settled dust sample collection) was used to stir up the settled surfac e dust before the air sampling began. d. f/cc = the fibers in each cubic centimeter (cc) of air. Tfiis is calculated from the number of fibe rs seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. e. Scanning electron microscopy (SEM) and TEM resu ts for these air samples are available and shown on Table S. f. ND = not detected.

62

CITY_21MC100_011109619

NYC-WTC_000276895

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276895Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

Compare copies and versions →