Other contaminants sampling, debris field, 2001-02

Machine-extracted title · confidence 26%

Miscellaneous sampling data on hydrocarbons, dioxins, Freon, and related substances at WTC debris area.

NYC-WTC_000276821–000276822
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

around the perimeter are lower than those found directly over the pile. To date, only one sample taken on the rubble pile showed dioxin levels which exceeded background levels. Dioxins are considered collectively as suspect human carcinogens. OSHA does not have a PEL for dioxins. Polynuclear Aromatic Hydrocarbons OSHA has taken 110 samples (excluding blanks). The majority of the samples have not shown the presence of benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons: anthracene , acridine. pyrene, chrysene and phenanthrene. Sample results to date liave identified eight samples which reached or exceeded OSHA’s coal tar fdtch volatile PEL of 0.2mg/m’. These personal samples were taken on the pile on iron workers and grappler operators. OSFL/i continues to recommend the use of respiratory protection when working in the debris field. FreonR-22, Hydrogen Fluoride & Phosgene: OSHA has taken a total of 214 samjales for Freon R-22 (chlorodiflouromethane), hydrogen fluoride, and phosgene. Only one Freon sample resulted in a detectable level of 6.4 ppm during the transfer of Freon from the auxiliary chiller, and all other samples were none-detected. OSHA does not have an exposure limit for Freon R-22. (The NIOSH REL for Freon is lOOOppm..) Sampling for the decomposition products of Freon R-22, hydrofluoric acid (HF) and phosgene showed no detectable levels.

Inorganic Acids OSHA has taken approximately 213 samples for inorganic acids such as hydrochloric, phosphoric, and sulfuric acids. Three samples; for sulfuric acid were found to exceed OSHA’s permissible exposure limit (I’EL) of 1 mg/m\ Workers were sorting debris. Oxides of Nitrogen/ Sulfur: Sampling on grappler operators on the rubble pile, and on employees at the truck wash stations revealed Pace levels of nitric oxide and nitrogen dioxide. SO; personal and area results were found to be below OSHA limits.

Page 3 of 4

CITY_21MC100_011109472

NYC-WTC_000276821

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276821Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →