NYC 9/11 Public Portal Document
OSHA SAMPLING RESULTS SUMMARY AS OF 11/16
Asbestos: A total of652 air monitoring samples for asbestos have be en taken. From 9/13
-9/21, 177 samples were taken in the financial district. They were taken on
OSHA personnel as they walked within certain predetermined zones. Results
revealed asbestos concentrations ranging fiom ND (none detected) to .037
fZcc., well below OSHA’s penniss ible exposure limit (PliL) of .1 ficc.
After 9/21, sampling focused on th s rubble pile and those workers working on
or immediately next to it 63 of flie samples analyzed exceeded OSHA’s limit
via PCM analysis. However, uj)on further analysis using discriminating
counting methods and/or TEM anidysis, the number of asbestos fibers found
dropped dramatically to below detectable levels or well below .117cc.
Carbon Monoxide: A total of 47 personal samples of workers on the rubble; pile showed results
ranging fi-om 1 ppm to 34 ppm which are well belov' the OSBA 50 ppm
permissible exposure limit.
Noise: OSHA has been conducting noise monitoring in the rubble pile. Twelve
personal samples have been conducted on employees performing (or working
near) various operations such iis jack hammering. Employee’s exposure to the
noise range from 80.6 dBA to 89 dBA. OSHA’s permissible noise exposure
for construction is 90 dBA
Respirable
SiUca: The overwhelming maj ority ofthe 240 silica samples show no detectable levels
of airborne silica. Howver, the highest sample result was approximately nine
times the OSHA limit on pre-dril lers working on the ba.thtub wall. The next
highest level was twice the OSHA. limit during rubble removal and loading
operations near the Winter Garden. Both of these levels were found on
persoimel working in the rubble; pile; an area where OSHA continues to
encourage the use of respiratory protection.
Volatile Organic
Compounds: OSHA has taken 366 samples for (VOCs) such as acetaldehyde, acrolein,
acrylonitrile, benzene, 2-butanoni3, carbofurans, chlorodiphenyl (PCB), ethyl
benzene, formaldehyde. Freon R-22 (chlorodiflouromethane), hexone,
isocyanates (e.g. MDI, TDI), perchloroethylene, phosgene, styrene, toluene,
1-3 butadiene, trichloroethylene;, vinyl chloride, and xylene. Screening
samples initially showed elevated levels of some organic chemicals resulting
from the fires burning in tlie nibble pile. Subsequent personal and area
samples show worker exposure levels to be below OSHA. limits. However, one
personal sample result for ben;:ene was found to be at the 8-hr. OSHA
Allowable Limit concentration of 1 ppm. This was found on a backhoe
operator moving debris. See information below for polynuclear aromatics.
Freon R-22, phosgene and dioxin.
Oxides of Nitrogen/
Page 1 of 2
CITY_21MC100_011109443
NYC-WTC_000276794
OCR can misread numbers and units. Confirm readings against the page image before using them.