NYC 9/11 Public Portal Document
INTERNAL REVIEW DRAFT
2.B.I. Personal Protective Equipment
The Study was conducted using the following levels of protection: Level D+ : This level of
protection requires employees to wear safety glasses, disposable coveralls (Tyvek), disposable
head coverings, disposable undergarments, disposable gloves, disposable boot covers, steel-toed
boots, and hearing protection (if applicable). Level C: This level of protection requires
employees to supplement the above with an air purifying respirator (half face or full face PAPR)
equipped with Pl 00 cartridges. Comprehensive information relative to personal protective
equipment is contained in the Health and Safety Issues, Attachment 6, and the Health and Safety
Plan, Attachment 7.
2.B.2..Safety Risks
At project onset, all units and common areas were inspected to assess building condition and to
identify safety risks such as: gas, oil, and water leaks; perishable foods; rodent/insect
infestations; damaged floors, walls, stairways, and elevators. All safety risks identified were
eliminated prior to commencement of cleaning activities. The safety risks identified included
electrical concerns, necessary building repairs, building access concerns, and rodent infestation.
For additional details, please see the Health and Safety Issues, Attachment 6, and the Health and
Safety Plan, Attachment 7.
2.C. Equipment
In the aftermath of the WTC attack, vacuums were made available to the general public by The
American Red Cross and a vacuum reimbursement program was established by the Federal
Emergency Management Agency (FEMA). The vacuums made available to the public included
vacuums with HEPA-filtration made by Eureka, Hoover and Mastercraft. Shop vacuums
produced under the Ridgid brand and Craftsman brand were also observed in use by residents of
lower Manhattan, in the wake of the attack. Typically used in industrial settings, high efficiency
particulate air (HEPA) filters are capable of trapping and retaining at least 99.97% of all
mono-dispersed particles of 0.3 micrometers in diameter. The Study tested cleaning using
vacuums with and without HEPA filtration.
An Air Filtration Device (AFD) is a local exhaust system with HEPA filtration that is capable of
creating and maintaining a negative pressure differential between the outside and the inside of the
work area. The AFD functions as a stand-alone piece of equipment in a room. During the Study,
the AFD was used as an air-polishing device, to capture dust particles that became airborne as a
result of disturbances caused by the cleaning activities. The Study tested cleaning with and
without use of Air Filtration Devices.
ERA selected equipment similar or identical to the equipment observed in use by residents of
lower Manhattan after the attack on the World Trade Center, and tested use of this equipment in
performing the cleaning of residential apartments at the project Site. A commercially produced
vacuum made by Nilfisk Advance Systems was selected to provide industrial strength vacuuming
technology, because many management companies who cleaned residential and commercial
12
CITY_21MC100_004204969
NYC-WTC_000276665
OCR can misread numbers and units. Confirm readings against the page image before using them.