Post P' Cleaning Samples, Test 4D - There were three air samples collected after cleaning. All of the air samples were below the detection limit and below the primary numeric criterion of 10 S/L.

PAHs Before Cleaning Samples - There was one pre-cleaning air sample and three pre­ cleaning wipe samples collected. The air sample was below the detection limit and the TEF was below the primary numeric criterion of 0.2 p.g/m\ Two of the three wipe samples had PAH compounds detected. One sample detected three PAH compounds and the other detected two PAH compounds. The calculated TEFs for these two samples, as well as the third sample, were below the primary numeric criterion of 300 pg/m^

Post Cleaning Samples, Test 4A - There were four post-cleaning wipe samples collected. All four samples were below the detection limit and the TEF for each sample was below the numeric criterion of 300 pg/nr.

Post P‘ Cleaning Samples, Test 4B - There were four post-cleaning wipe samples collected. All four samples were below the detection limit and the TEF for each sample was below the numeric criterion of 300 pg/m^.

Post P' Cleaning Samples, Test 4E - There were two post-cleaning wipe samples collected. Both samples were below the detection limit and the TEF for each sample was below the numeric criterion of 300 p-g/mf

Total Dust Before Cleaning Samples - There were three pre-cleaning wipe samples collected; however, EPA only requested to have one of the samples analyzed. The results indicate that dust was present.

Post P' Cleaning Samples, Test 4A - There were four post-cleaning wipe samples collected; however, EPA only requested to have one of the samples analyzed and another sample was received broken at the laboratory. The sample which was analyzed indicates that dust was present at concentrations lower than the pre-cleaning concentrations.

Post P' Cleaning Samples, Test 4B - There were four post-cleaning wipe samples collected; however, EPA only requested to have two of the samples analyzed. The samples which were analyzed indicate that dust was present at concentrations lower than the pre-cleaning and Test 4A concentrations.

111

CITY_21MC100_004205067

NYC-WTC_000276763

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276763Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000243565

EIA report for Law Department project at 100 Church Street by TRC.

Similar indexed content

Compare copies and versions →