Exposure evaluation report, WTC site, Oct 2002

Machine-extracted title · confidence 55%

EPA/NCEA draft on exposure and [name] evaluation relating to World Trade Center.

NYC-WTC_000276455–000276612
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

inadequate, but suggestive of PCB carcinogenicity.

From the dose-response data derived from animal studies, the EPA has calculated an upper bound cancer slope factor of 1* UU [pg/m^]"' associated with continuous lifetime inhalation exposure to PCBs. This slope factor pertains to exposure to total PCBs, which may or may not contain dioxin-like PCBs. For exposure to dioxin-like PCB congeners alone, the slope factor developed for dioxin-like compounds should be applied (EPA, 2000a). This assessment does not consider exposure and risk from dioxin-like PCBs because these congeners were not measured separately. The Toxic Equivalent (TEQ) concentrations discussed in the dioxin section below are specific to dioxin and furan congeners only.

A cancer risk from a less-than-lifetime inhalation exposure to total PCBs is given as:

Risk = LAC* UR (2)

where LAC is the air concentration averaged over a lifetime, calculated as; AC * [ED/LT], where AC is the average air concentration during the period of exposure (pg/m '), ED is the exposure duration (days), LT is lifetime (days), typically 70 years, and UR is the unit risk factor, expressed in units of 1/concentration.

In order to conduct a simple screening exercise to evaluate the cancer risk from inhalation of elevated levels of PCBs near the WTC site, a representative air concentration and a time during which exposure to that concentration occurred need to be determined. The areas in which PCB air concentrations were elevated were generally located within the “restricted zone”. Still, even if an individual were exposed to the highest concentration found at 153 ng PCB/m’ for a period of 1 month (and all the data suggests that elevations did not exist beyond 1 month), the lifetime cancer risk would be estimated at about 2*10 ** (calculated as: [0.153 pg/m^] * [30 days/ (70 years*365 d/yr)] * [1*10'“* (pg/m^) ']). EPA regulatory programs, such as the Superfund Program, typically consider individual incremental cancer risk estimates made in this manner (i.e., in the context of a scenario-based risk assessment) in the range of IO”* to 10'’ to be of potential significance, depending on the circumstances. On this basis, an incremental cancer risk estimate in the range of 10'^ is judged to be insignificant.

ATSDR has published a Toxicological Profile for PCBs (ATSDR, 2000a). This Toxicological Profile is a comprehensive review and summary of existing health effects information relevant to human exposures. From this review, it is concluded that all the measured PCB levels in air in or around the WTC site were well below the levels of significant exposure to PCB mixtures that were found not to cause adverse effects in experimental animals as a consequence of short-term inhalation exposure. These no-observed-adverse-effect-levels (NOAELs) in experimental animals ranged from 1.5 x 10'' ng/m’ for renal effects to 9 xlO’ng/in’ for hepatic effects. These NOAELs are one to six orders of magnitude higher than the highest PCB air levels measured in Lower Manhattan.

Occupational exposure limits provide an additional perspective by which to evaluate potential non-cancer health effects that may be associated with inhalation exposure to PCBs measured in the air at or near the WTC site. NIOSH publishes RELs and OSHA publishes PELs

DKAl'T-DO NOT QUOTE ON CITE 68 October 2002

CITY_21MC1OO_O111O9O83

NYC-WTC_000276537

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276537Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →