.001 f/cc).

However, since only a minority of the sampling locations (6) had PCM counts above background, and hence were analyzed by TEM; results are not conclusive regarding the potential for low levels of airborne asbestos (i. e., at levels < 0.003 f/cc — fibers meeting criteria for optical visibility). In this regard it should be noted that the specific residences that had detectable asbestos in indoor dust did not have elevated airborne PCM levels and TEM data were not collected for these residences. Note that when conditions allowed the residential sampling utilized an "aggressive" methodology involving the operation of the vacuum exhaust, used for settled dust sample collection, to stir the air. Additionally, evidence of elevated asbestos levels was not found in air samples collected in common areas of the apartment buildings or in adjoining outdoor areas.

The NYCDOHMH/ATSDR Final report also Included data on synthetic vitreous fibers (SVF or fibrous glass) concentrations in indoor and outdoor dust samples at the same residential locations. SVF (PLM analysis) was detected in a larger number of indoor dust samples (26 of 57 or 46%) and at higher concentrations (range 2-35%) than asbestos. In outdoor dust at these properties, SVF was detected in 11 of 14 (79%) of samples (concentration range 15 - 72%). As with asbestos, the study did not provide evidence of airborne SVF above background levels in indoor air samples collected at the residences in lower Manhattan. PCM measurements will detect SVF, and in those locations where air samples had total PCM fibers exceeding background, Scanning Electron Microscopy (SEM) also reexamined filters for SVF. While such fibers were detectable in two samples, all samples were below 0.001 f/cc.

Air and settled surface dust samples were also analyzed for mineral components of concrete (quartz, calcite, and portlandite) and mineral component of building wallboard (gypsum, mica, and halite). The X-ray diffraction analysis (XRD) analysis for ciystalline minerals in air and settled surface dust is reported by NYCDOHMH/ATSDR as semiquantitative (labeled with a “J”). Air sampling for minerals detected quartz and other building-related materials in lower Manhattan. The other forms of crystalline silica were not detected in any air samples except for a one-time detection of cristobalite. The estimated concentrations of these minerals in air were low. In some locations, mineral components of concrete (quartz [3-19 pg/m’J], calcite [ND-14 pg/m’J], and portlandite [ND-95 pg/m’J]) and mineral components of building wallboard (gypsum [4-15 pg/m^J] and mica |\D-43 pg/m^J]) were detected in air samples at higher estimated levels in lower Manhattan residential areas than in samples taken at comparison residential areas above 59th Street (quartz up to 6 pg/m\J. calcite up to 6 pg/m’J, portlandite up to 30 pg/m^J, gypsum up to 6 pg/m^J, and mica up to 17 pg/m’J). Quartz, calcite, portlandite and gypsum appear to make up a higher percentage of dust in some buildings in lower Manhattan when compared to settled surface dust samples from buildings above 59th Street. Quartz was detected up to an estimated 31%J versus up to 2%J found in the comparison areas above 59th Street. Neither cristobalite nor tridymite was detected in any of the settled surface dust samples. Similarly gypsum was found at a maximum estimated concentration of 30%J in settled surface dust, higher than the 4%J estimated in the comparison areas above 59th Street. Calcite and portlandite had maximum concentrations of 21%J and 8%.I respectively. At lower Manhattan locations sampled, quartz was detected in 81% of common areas and 53% of residences. Gypsum was seen in 88% of common areas and 79% of residences. Minerals were

DliAl'T-DO NOT QUOTE OR CITE 129 October 2002

CITY_21MC100_011109144

NYC-WTC_000276598

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276598Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000148952 · Box DEP Box 10

Data table listing specific street locations outside the World Trade Center site where volatile organic compound sampling was conducted.

Similar indexed content

NYC-WTC_000348699

COPC committee report with contributors from EPA, NYC DEP, and state agencies.

Similar indexed content

NYC-WTC_000348649

COPC committee report on World Trade Center contaminants with multi-agency authors.

Similar indexed content

Compare copies and versions →