NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 414 pages

Ground Zero environmental health schools report

Machine-extracted title · confidence 45%

Document discussing lessons learned in children's environmental health related to Ground Zero sites.

NYC-WTC_000276036–000276449
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

AMBIENT AIR AND DUST SAMPLING PROTOCOL for PS234M. Page 6 of 7

• Two Classrooms facing south - 2 samples (one sample in each randomly selected classroom immediately after the last class)

• Classroom facing east - one sample in a randomly selected classroom immediately after the last class.

All sample collected shall be analyzed utilizing the NIOSH 7500 method for respirable silica.

Since, there are no regulatory standards for Mineral Dust in non-industrial buildings, such as offices and schools at this time, the OSHA standard 1910.1000 TABLE Z-3 shall be utilized (per the request of PA consultant).

Results from samples collected shall be reported to BOE, LIFT, School Principal and the PA consultant within 72 hours from the collection day.

In the event that unsatisfactory results are obtained, the following actions are to be implemented;

1. Perform general dust clean up of all areas/classrooms with unsatisfactory results. 2. Re-test said areas following clean up. 3. Floor mats and/or other dust control devises shall be placed at points of entry.

Actions 1,2 shall be repeated until satisfactory results are obtained.

DIOXIN WIPE SAMPLES

• First floor hallway .east end. near main entrance - one sample • First floor hallway west end. near west playground exit - one sample

All sample collected shall be analyzed utilizing the EPA 8290 PCDD/DF Dioxin Furan method.

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant in 15 business days from the day of sampling.

In the event that any one sample result is unsatisfactory BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

PCB WIPE SAMPLES

• First floor hallway .east end. near main entrance - one sample • First floor hallway west end. near west playground exit - one sample

All sample collected shall be analyzed utilizing the EPA 8081 method.

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant in 4 days from the day of sampling.

CITY_21MC100_012173122

NYC-WTC_000276277

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276277Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →