Mr. Craig Levine Director of Special Project Office of the Chancellor New York City Board of Education 110 Livingston Street, Room 1025 Brooklyn, New York 11201

FAX; 718-935-3463 Copy: Mr. Charles Collins: FAX 718-391-6909 Re; 2-01-02 e-mail; Attachments to R. Casconc 2-01-01 e-mail response

The following artachments are provided for your reference regarding the filtration installed at Stuyvesant High School.

Attacliment 1: NAFA Guide to Air Filtration Page 9.5 Table 9.1 a - In addition to EPA 2.5PM paniculate standards - Bums and Roe has evaluated the indoor air quality at Stuyvesant based on criteria of 1,000,000 particles over .3 um in size. This is comparable to a M6 classification.

Page 10.5 Table 10.1 For all central air handling luiit at Stuyvesant we have installed pre-filters (OdorGuard III) and after filters. Tri-Dim 4 ply MERV Rating of 9 and 24”x24”x30” deep bag filter MERV rating of 14.

For the Tri-Dim 4 ply MERV Rating 9 we exceed filter efficiencies for central healtli car e ventilation systems for administrative areas. For the 24”x24’’x30” deep bag filler MERV rating of 14 fillers (HVAC 1, We exceed the criteria for in-patient care for all health facilities referenced.

Page 12.7 of the Guide indicates a MERV 6 rating for schools. We exceed tliis criterion for all filters except for the classroom unit ventilators due to the current need to provide a charcoal-activated filter for odor control. These types of filters arc not rated per AHSRAE 52.2 test inetliod for paniculate filtration. Once odor or VOC filtration is no longer an issue a filter of MERV 9 or MERV 11 can be installed for particulate filtration only.’

Attachment 2 OdorGuard Literature Tri-Dim 4 Ply Filter data and Test Dara Tri-Dim 24”x24”x30" deep Bag Filter Test Data

Attachment 3 WACO Air Filter Application Guide MERV Ratings 1 -20

Attacliment 4 PowerGuard Literature - Alternate filter for 4 ply or OdorGuard in Unit Ventilators for particulate filtering only.

Attachment 5 Quote for ParticIeScan Counter

CITY_21MC100_012173040

NYC-WTC_000276195

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276195Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →