Stuyvesant High School Letter Report

Meeting Date: Tuesday November 20,2001

Location: Stuyvesant High School 345 Chambers Street New York, NY 10262

Subject: Indoor Air Quality Concerns HVAC Rehabilitation Program

Participants: Burns and Roe Stuyvesant HS

Robert Cascone Peter Lopa

Air Engineering Stuyvesant HS Parents Association

Lawrence Conley. Jr. Howard Bader

PURPOSE OF THE MEETING:

Burns and Roe reviewed the filter and HVAC modifications proposed by Howard Bader the Environmental Consultant representing the Parents Group of Stuyvesant High School. Burns and Roe also contacted Air Engineering, the company presently supplying air filtration products to Stuyvesant High School, was also contacted by phone to discuss the filter retrofits proposed by Howard Bader and the Parents Group. It was decided to have a joint field survey to determine feasible filter retrofits that could be accomplished with the existing HVAC systems. This Letter Report provides the results of the field survey and the recommendations proposed on a trial basis to improve filtration and indoor air quality.

DISCUSSiON:

Since time is of the essence, the recommendations proposed in this report are suggested to be done on a trial basis and the performance verified by the existing particle count program and indoor air qualify monitoring program already established and in place.

Many of the proposals require additional filtration. The additional filtration will increase the static pressure of the supply fan systems. The end result will be a decrease in supply air cfm (cubic feet per minute), and a loss of the economy cooling cycle for the unit ventilators. The detrimental HVAC effects proposed by these emergency short term effort to increase indoor air quality should be measured by an air balance and testing contractor during the retrofit process to field verify the actual amount of system degradation. Once field measurement data is obtained it will be compared to empirical fan curve data and HVAC calculations to determine HVAC modifications required on a long-term basis.

Additional engineering effort will be required to support the long term solution.

CITY_21MC100_012172993

NYC-WTC_000276148

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000276148Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000106411 · Box DEP Box 37

Union memorandum regarding environmental monitoring and cleanup protocols following the closure of Stuyvesant High School after the September 11 attacks.

Similar indexed content

NYC-WTC_000149798 · Box DEP Box 10

Generic form or header page from the Department of Environmental Protection regarding general World Trade Center notices and requests.

Similar indexed content

Compare copies and versions →