3. Alkalinity of Settled Surface Dust

Several of the minerals detected in the settled surface dust samples, such as portlandite, can make the dust more alkaline, or raise the pH. Originally, the pH of all of the settled surface dust samples was to be determined. However, enough dust for this analysis was only available at two locations. Both dust samples were alkaline (pH of 8.6 and 9.8). On the pH scale of 0 (acidic) to 14 (alkaline or basic), these values are slightly alkaline. Mineral analysis of these two settled surface dust samples estimate levels of calcite (15%J, 19%J) and portlandite (6%J, 3%J) were present, respectively. These crystalline minerals along with other components of concrete would have contributed to the measured alkalinity.

C. Air

The settled surface dust results discussed previously indicate the materials present in each area sampled. Fibers and small particles within the dust may become airborne during daily activity or during periods of high activity such as cleaning. Therefore, the settled surface dust sample results are an indicator for areas with a potential for airborne contaminants. Air sampling was conducted to determine the actual levels of fibers, dust, and crystalline minerals in the air at the time of settled surface dust sampling. Where feasible, these results are correlated to the settled surface dust results.

1. Fibers in Air

Samples for airborne fibers were first analyzed by phase contrast microscopy (PCM) to count all fibers present according to the National Institute for Occupational Safety and Health (NIOSH) Method 7400 counting rules. Phase contrast microscopy identifies fibers based on size and shape, but not the specific type of fiber. Therefore, the fibers seen by PCM include asbestos fibers as well as other fibers, such as textiles, fiberglass, and cellulose that might be present. Any sample with airborne fibers above the highest PCM levels found in the comparison locations was re-analyzed by transmission electron microscopy (TEM) and scanning electron microscopy (SEM). The TEM methodology can distinguish what types of fibers are in a sample, particularly asbestos fibers. The SEM method identifies SVF. Some fibers present in the settled dust of the area may become suspended in the air and be present in the air sample.

a. Indoor Air

Fiber levels in air are expressed as the number of fibers in each cubic centimeter (cc) of air or fibers per cc (f/cc). Low levels of fibers were found in the comparison areas above 59th Street homes, where fiber levels ranged from less than 0.001 f/cc (<0.001 f/cc) to 0.003 f/cc. Because no asbestos was detected in the settled surface dust of the comparison areas above 59th Street, these fibers are not likely to have been asbestos. SEM analysis showed they were not SVF. Figure 7 shows all airborne fiber levels determined by PCM in the lower Manhattan area with respect to the fiber levels found in the comparison areas

23

CITY_21MC1OO_O111O8894

NYC-WTC_000275970

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275970Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000276826

Final investigation report on airborne exposures to dust at World Trade Center recovery site.

Similar indexed content

NYC-WTC_000301668

Final report on airborne and [name] dust exposures in Lower Manhattan related to WTC events.

Similar indexed content

NYC-WTC_000275863

Investigation report on exposures to airborne and dust in Lower Manhattan.

Similar indexed content

Compare copies and versions →