Asbestos air test results, 250 [name] Avenue, Nov 2001

Machine-extracted title · confidence 25%

Summary of asbestos air testing results for 250 [name] Avenue, with locations and materials analyzed.

NYC-WTC_000275382–000275385
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Summary ofAsbestos Sampling Results Page 2 of 4 Address: 250 South End Date sampled: November 14, 2001

Results of Phase Contrast Microscopy (PCM) testing of 250 South End Avenue, November 14, 2001 ........................ - I ■ - ■- .p - - i 1 - — Il Area Sampled Outside Common Residence 1 Residence 2

Sample Numbers A-C-2 A-Rl-2 A-R2-2 A-0-2

Concentration of Fibers in Air 0.003 0.005 <0.001 0.002 at this location (f/cc)*

Concentration of Fibers in Air <0.001 to 0.001 <0.001 to 0.002 <0.001 to 0.003 <0.001 to 0.003 at background locations (f/cc) NYC Re-occupancy 0.01 0.01 0.01 0.01 Standard (f/cc)** * f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. ** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York, Title 15, Chapter 1)

Asbestos in air as determined by TEM analysis: TEM analysis is very specific and can distinguish between asbestos and non-asbestos fibers, such as textiles, fiberglass, or cellulose. This analysis determines if the fibers seen in the PCM analysis are asbestos, or if they are some other material. TEM analysis was conducted on all air samples that showed more than 0.003 f ee in the air by PCM analysis. No asbestos fibers were found in the TEM analysis of the air samples in your building where PCM levels exceeded 0.003 f/cc.^

Results of Transmission Electron Microscopy (TEM) testing of 250 South End Avenue, November 14, 2001__________________________________ Area Sampled Common

Sample Numbers A-C-2 Concentration of Asbestos Fibers in Air at this location <0.001 (EceP^,_______________________________________ Concentration of AU Fibers in Air at background locations <0.001 to 0.003 (fee)________________________________________ NYC Re-occupancy Standard (f/cc) ** 0.01 * f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters. ** New York City Department of Environmental Protection asbestos clearance criteria for post-abatement work (Rules of the City of New York, Title 15, Chapter 1)

" The TEM method employed here, NIOSH 7402, counts fibers of the same size as those detected by PCM analysis. Fibers reported here are greater than or equal to 5 microns in length and 0.25 microns in width.

CITY_21MC100_006814994 NYC-WTC_000275383

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275383Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →