NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 5 pages

EPA ultrasonication labs list, carpets

Machine-extracted title · confidence 37%

Memo listing labs offering EPA ultrasonication test for carpet dust asbestos content.

NYC-WTC_000275360–000275364
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

UNITED STATES ENVIRONMENTAL PROTECTION AGENCY WASHINGTON, D.C. 20460

OFFiCE OF SOLID WASTE AND EMERGENCY RESPONSE MEMORANDUM

DATE: July 3, 2002

SUBJECT: 1. UPDATED LIST - LABS FOR EPA’s ULTRASONICATION TEST FOR CARPETS

2. EPA WILL TRY TO REVERSE EARLY STUDIES SHOWING HEPA VACUUMS INEFFECTIVE

FROM: Cate Jenkins, Ph.D.* [email protected] Waste Identification Branch (Mail Code 5304 W) Hazardous Waste Identification Division

TO: Affected Parties and Responsible Officials

This memorandum lists additional laboratories known' to offer EPA’s ultrasonication test for dust in carpets and woven fabrics.^ This state-of-the-art test gives results as the number of asbestos structures per square centimeter (s/cm^). The results can then be related to background levels and safety guidelines. A major advantage in this test is that you do not need a consultant or industrial hygienist to take samples. The lab cost for an ultrasonication test ($ 120 - $300) is not substantially more than for a microvacuum test (around $150), which would require an additional consultant fee.

This memorandum is an addendum to my 6/9/02 memorandum “Carpets, the Asbestos Reservoir” which discusses the ultrasonication method in greater detail. It is posted at the New York Environmental Law and Justice web site at www.NYenviroLAW.org.

As discussed later, EPA announced that they would be testing the effectiveness of HEPA vacuuming for removing asbestos from WTC fallout. However, EPA is only going to test the carpet after vacuuming with a microvacuum sampler. EPA apparently wants to justify its flawed cleanup method and reverse the results of its own earlier studies, which used the sonication extraction method to evaluate the effectiveness of HEPA vacuums.

’ The conclusions and opinions in this memorandum are those of the author and do not necessarily reflect those of the U.S. Environmental Protection Agency.

CITY_21MC100_0 12171550

NYC-WTC_000275360

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275360Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000433249

Addendum listing laboratories offering EPA ultrasonication tests for fabrics/dust.

Similar indexed content

Compare copies and versions →