NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

WTC site sampling overview, worker exposure

Machine-extracted title · confidence 40%

Table of samples and worker exposure roles at WTC site; metals and particulates listed.

NYC-WTC_000275291
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Draft Proposed Sampling Strategy for the WTC Site: 9/25,Til

co CD Task Potential Hazards Minimum Number of cu Samplcs/Day

Iron workers (torch cutters, etc.) Metals, Fire decomposition productst, Carbon monoxide, Ozone, Asbestos 6 to 10

Fire fightcrs/policc (on debris pile) Fire decomposition products!, Carbon monoxide, Asbestos 7 6 to 10

Fire fightcrs/policc (off debris pile) Diesel exhaust 2 to 5

Heavy equipment operators (crane, bobcat, Fire decomposition products!. Carbon monoxide. Noise, Asbestos 6 to 10 >- front-end loaders, high reach machines) co LO USAR (urban search and rescue teams) Fire decomposition productst. Carbon monoxide. Asbestos 6tol0 CO w—• Lf) Traffic controllers in the restricted area Carbon monoxide, Diesel exhaust, Noise 2to5 O :z: Diesel exhaust, Asbestos Truck drivers (leaving the site) 2to5 su. Site access personnel (i.c. checkpoints on the Carbojwnonoxidc 7 ( 2to5 perimeter of tlic site)

t For the WTC site, (he fire decomposition products group is defined to include the following aromatic hydrocarbons: toluene, xylene, and ethylbenzene. Total hydrocarbons (quantified as undecane [CiJ and reported in milligtams per cubic meter) should also be reported.

Suggested sampling methods:

Metals:NIOSH Method 7300 - Elements I Carbon monoxide; Direct-reading dosimeter Diesel exhaust: NIOSH Method 5040 Aromatic Hydrocarbons: NIOSH Method 1501 2 5 Noise; Type II noise dosimeters (initial characterization may be done with a Type ft sound level meter) E Ozone: Direct-reading instrument Ql. Asbestos: NIOSH 7400 (PCM), NIOSH 7402 (TEM) Q O H CO 1 K o Other potential exposures: I—i s , NlOSFl investigators have collected samples for the following substances and arc currently awaiting the analytical results: polynuclear aromatic hydrocarbons O ! o o [PAHs]: mercury; crystalline .silica, polychlorinated biphenyls (PCBs). o o Io Cd I o LO NOTE: Those with oversight responsibilities for characterizing occupation.il exposures at (he WTC site should be cognizant of the fact (hat this work site is a CVJ <75 I CO Cl. dynamic environment and worker exposures may change depending on weather conditions and ty-pc of debris being rcmoved.Jnic type of personal LU CO monitoring may need to be adjusted based on these factors. ) o

NYC-WTC_000275291

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275291Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000407825

Tabulated sampling plan for workers and responders; targets metals, asbestos, and related exposures.

Similar indexed content

Compare copies and versions →