Action levels (Ecc) for workers Disaster Response and Recovery Workers Basis Comments involved in emergency response (follow applicable OSHA standards) and recovery activities 0.1 PCM only • Respiratory protection required for PEL Value, 0.1 f/cc based on an eight hour time weighted workers, based on an 8 hour time weighted average, is the Occupational Safety and Health average (TWA) of exposure of 0.1 PCM. Administration’s (OSHA) Permissible Exposure Longer shift work, i.e., lower levels of Limit for asbestos, as specified in the OSHA exposure Construction Industry Regulation.for Asbestos, 29 (i.e., the proportional maximum exposure CFR 1926.1101. for a 12-hour shift is 0.07 f/cc PCM).

1.0 PCM only • The maximum allowable level for STEL Value, 1.0 f/cc measured over a 30-minute period, is workers average over 30 minute period the Occupational Safety and Health Administration’s (OSHA short term exposure level). (OSHA) Short-Term Exposure Limit for asbestos, as • PPE required above 1.0 f/cc PCM. specified in the OSHA Construction Industry Regulation for Asbestos, 29 CFR 1926.1101.

1. General public includes adults and children not directly involved in emergency response and recovery activities. 2. Background levels for NYC being determined. 3. PCM equivalents (PCMe) is determined using TEM analysis and counting fibers > 0.3 ^m in diameter and > 5 ,wm in length. PCMe should be determined using consistent methods to provide comparable concentrations. If PCM is exceeded, may need to determine PCMe using TEM. Use professional judgement to determine if PCMe is needed by evaluating the frequency and magnitude of exceedance, size of geographic area involved, and trends in data.

o H

I o o I o o cn co I—i

NYC-WTC_000275284

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275284Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →