NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

WTC industrial hygiene data memo

Machine-extracted title · confidence 45%

ATSDR/CDC/OSHA data and recommendations for WTC response.

NYC-WTC_000275273–000275274
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Action levels (fZcc) for workers involved Disaster Response and Recovery Workers Basis Comments in emergency response and recovery (follow applicable OSHA standards) i' I. activities 0.1 PCM only • Respiratory protection required for PEL Value, 0.1 f/cc based on an eight hour workers, based on an 8 hour time weighted time weighted average, is the average (TWA) of exposure of 0.1 PCM. Occupational Safety and Health Longer shift work, i.e., lower levels of Administration’s (OSHA) Permissible exposure Exposure (i.e., the proportional maximum exposure for Limit for asbestos, as specified in the a 12-hour OSHA Construction Industry Regulation shift is 0.07 f/cc PCM). for Asbestos, 29 CFR 1926.1101. 1.0 PCM only • The maximum allowable level for workers STEL Value, 1.0 fZcc measured over a 30- average over 30 minute period (OSHA short minute period, is the Occupational term exposure level). Safety and Health Administration’s • PPE required above 1.0 £/cc PCM. (OSHA) Short-Term Exposure Limit for asbestos, as specified in the OSHA Construction Industry Regulation for Asbestos, 29 CFR 1926.1101.

1. General public includes adults and children not directly involved in emergency response and recovery activities. 2. Background levels for NYC being determined. 3. PCM equivalents (PCMe) is determined using TEM analysis and counting fibers > 0.3 pm in diameter and > 5 /zm in length. PCMe should be determined using consistent methods to provide comparable concentrations. If PCM is exceeded, may need to determine PCMe using TEM. Use professional judgement to determine if PCMe is needed by evaluating the frequency and magnitude of exceedance, size of geographic area involved, and trends in data.

C:\Environmental\Emails\NewData_9_27\NancyKim_asbestosActionLevel_Final.wpd o H

S o o o I o o Ob co

Ob o kO

NYC-WTC_000275274

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275274Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →