NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Air sample analysis, Stuyvesant HS, Jul 2002

Machine-extracted title · confidence 44%

NIOSH 7082 air sample analysis report for Stuyvesant HS project.

NYC-WTC_000275222
Page image
Scanned page image, NYC-WTC_000275222
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC ASSOCIATES, INC I 104 E 25th Street, 10th Floor New York, NY 10010

I TeL 212-353-S280 Fax 212-353-8306

REPORT DATE; 07-30-02

I CLIENT: Taylor Environmental Group, Inc.

PROJECT NAME: SCA/Stuy\'csant HS I 2nd Floor

PROJECT NUMBER: M477-15217/29881

I SAMPLED BY: Client

SAMPLE DATE 07-29-02 I DATE RECEIVED: DATE ANALYZED: 07-29-02 07-29-02

SAMPLE MEDIA: Air Samples ANALYSIS REQUIRED; Method NIOSH 7082

I .ANALYSIS RESULTS

SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION I ID NO. CONCENTRATION LIMIT (gS/m*)

I 1 -> 20745 20745 Inside Rm 207 at Entrance to Corridor Inside Rm 209 at Entrance to Corridor <3.1

<3.1 3.1

3.1 3 20745 Inside Rm 229 at Entrance to Corridor <3.1 3.1

4 20745 Inside Rm 235 at Entrance to Corridor <3.1 3.1

5 20745 Inside Rm 237 at Entrance to Corridor 3.2 3.1 6 20745 Inside Rm 250 at Entrance to Corridor <3.8 3.8

I 7

8 20745 20745 Inside Rm 251 at Entrance to Corridor Field Blank <4.9 4.9

<1-5 RS 1-5 HE

9 20745 Field Blank <1-5 ug 1-5 jJte

I NOTE 1:

I THE REPORTING LIMIT (RL) IS 3-0 pg * NOTE 2: At the present time there are no regulatory levels or requirements for indoor airborne lead in area samples. However, OSHA his established an action level of 30 pgZm’ and v permissible exposure level (PEL) of 50 pg/m’ for personal samples.

I NOTE 3; Blank units arc in pg

I CITY_21MC100_011108389 NYC-WTC_000275222

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000275222Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.