NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Lead exposure discussion, health study references

Machine-extracted title · confidence 30%

Discussion of lead exposure contexts and occupational study references.

NYC-WTC_000274887
Page image
Scanned page image, NYC-WTC_000274887
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

LEAD

5. POTENTIAL FOR HUMAN EXPOSURE

sampled had airborne lead exposures exceeding the OSHA standard of 0.05 mg/m^ (Tharr 1993). Also, past studies of PbB levels of 56 radiator shop mechanics in the Boston area revealed that 80% had PbB levels greater than 30 P-g/dL and 16 had PbB levels exceeding 50 pig/dL (Thair 1993).

Studies have been conducted to determine exposure of firearm instructors to lead at outdoor firing ranges when either nonjacketed (pure lead) or jacketed (copper-coated) bullets were used. Instructors are likely to have higher exposure than shooters because they spend more time at the range. In studies at an out­ door range in Virginia, the mean breathing zone lead level when nonjacketed bullets were fired was 67.1 p.g/m^ for one instructor and 211.1 p.g/m’ for another (Tripathi et al. 1991). When jacketed bullets were used, breathing zone levels decreased to 8.7 p.g/m^ or less. PbB levels of the instructors did not exceed the OSHA return standard of 1.93 p.mol/L (40 p.g/dL) or removal standard of 2.4 p.mol/L (50 pig/dL) in either case. When shooters fired conventional lead bullets, their mean exposures to airborne lead were 128 p.g/m^ in the personal breathing zone and 68 p.g/m’ in the general area. When totally copper-jacketed lead bullets were fired, the mean breathing zone and general area air sample concentrations were 9.53 and 5.80 p.g/m\ respectively (Tripathi et al. 1990). At an outdoor uncovered range in Los Angeles, instructors who spent an average of 15 to 20 hours per week behind the firing line were found to be exposed to breathing zone lead concentrations of 460 and 510 pg/m^ measured as 3- hour, time-weighted averages. The PbB of one instructor reached 3.38 pmol/L (70 pg/dL). After reassignment to other duties, repeat testing indicated his PbB had dropped to 1.35 pmol/L (28 pg/dL) (Goldberg et al. 1991).

In 1991, NIOSH conducted a survey of the Federal Bureau of Investigations (FBI) Firearms Training Unit firing ranges and related facilities to determine occupational lead exposures among FBI and Drug Enforcement Agency (DEA) firing range personnel (NIOSH 1996). Sixty-one personal breathing-zone and 30 area samples for airborne lead were collected. Exposures ranged up to 51.7 ptg/m’ (mean 12.4 llg/m’), 2.7 Hg/m^ (mean 0.6 pg/m’), and 4.5 pgW (mean 0.6 p.g/m^) for range instructors, technicians, and gunsmiths, respectively. Exposure of custodians ranged fi-om non-detectable to 220 pig/m’ during short-term cleaning of a large indoor range. Carpet dust sampling of dormitory rooms of students who practiced at the firing ranges revealed statistically significant (p<0.0005) higher dust-lead concentrations when compared to non-student dormitories (dust-lead concentration range of 116 to 546 p.g/g with a geometric mean of 214 p,g/g in the student's rooms versus a dust-lead concentration range of 50 to 188 p.g/g with a geometric mean of 65 p.g/g for the non-student rooms). This suggested that the students were contaminating their living quarters with lead.

Field surveys of three radiator repair shops in the Cincinnati area revealed that local exhaust ventilation (LEV) systems are effective in controlling airborne lead levels. The highest concentration of airborne

NYC-WTC_000274887

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274887Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →