NYC-WTC_000383700
Memo re: indoor air quality measurements at PS 89M, Feb 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗ATC IAQ report for P.S. 89M dated Feb 26, 2002.
NYC-WTC_000274666–000274669OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan February 27, 2002 Indoor Air Quality Assessment Page 4 RR 89M ATC Project No. 15-19125-0297 individuals and children. The outdoor respirable particulate concentration measurements ranged from 28 to 36 pg/m^ with an average of 34 pg/m^.
* The measurements made during this assessment were ir stantaneous readings, the NPAAQS is a 24-hour average.
T7OC Concentrations
TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm.
OBSERVATIONS
During this assessment, ATC noted the following: • The school building was partially occupied (IS89) at the time of the assessment. • No smoke odor was detected m the building • The interior of the building appeared clean and free of dust and debris.
FINDINGS
Based on the real-time measurements, the following findings are presented:
1. Concentrations of CO, CO2 and TVOCs were within applicable standards and guidelines. 2. None of the indoor or outdoor PM2.5 measurements were above the NPAAQS of 65 pg/m^ or above the USEPA recommended PM2.5 concentration of 40 pg/m^ for sensitive individuals and children. 3. Twenty-seven (27) of the temperature measurements were above the range of 68 to 75° F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). 4. Forty-six (46) of the indoor measurements of relative humidity were within the ASHRAE recommended range of 30 to 60 percent for occupant comfort. All other measurements were below the ASHRAE recommended range.
It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 261 or 212.
Sincerely, Reviewed by: A TC ASSOCIA T£S INC.
lannis Efstathiou James R. Cohn, CIH, CSP Project Manager Regional Manager Industrial Hygiene Division Attachment
CITY_21MC100_003109845
NYC-WTC_000274669
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000383700
Memo re: indoor air quality measurements at PS 89M, Feb 2002.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383712
IAQ measurements report for PS 89M building, Feb 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382635
ATC IAQ measurements at P.S. 89M to evaluate school air quality.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382647
ATC memo detailing scope of indoor air quality evaluation at PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274654
IAQ measurements at P.S. 89M; February 25–27, 2002 evaluations.
13 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382671
ATC memo documenting IAQ evaluation scope at P.S. 89M.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400149
IAQ measurements report for PS 89M, March 2002, ATC.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400153
Indoor air quality measurements report for PS 89M, March 6-7, 2002, ATC.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400303
IAQ measurements at PS 89M for BOE; March 25, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383779
Indoor air quality measurements collected March 6, 2002 at PS89M for BOE evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383939
ATC report of IAQ measurements collected for BOE evaluation.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274710
ATC report of IAQ measurements conducted March 5, 2002 at PS 89M for NYC BOE.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000383712
IAQ measurements report for PS 89M building, Feb 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000382647
ATC memo detailing scope of indoor air quality evaluation at PS 89M.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000274654
IAQ measurements at P.S. 89M; February 25–27, 2002 evaluations.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383700
Memo re: indoor air quality measurements at PS 89M, Feb 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313893
ATC IAQ measurements collected June 18, 2002 at PS 89M per BOE request.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300673
ATC IAQ measurements at PS 150M for pre-occupancy evaluation.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000383700
Memo re: indoor air quality measurements at PS 89M, Feb 2002.
Similar indexed content
NYC-WTC_000383712
IAQ measurements report for PS 89M building, Feb 2002.
Similar indexed content
NYC-WTC_000382635
ATC IAQ measurements at P.S. 89M to evaluate school air quality.
Similar indexed content
NYC-WTC_000382647
ATC memo detailing scope of indoor air quality evaluation at PS 89M.
Similar indexed content
NYC-WTC_000274654
IAQ measurements at P.S. 89M; February 25–27, 2002 evaluations.
Similar indexed content