NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM analysis, lab sample dALsA, 70 s/mm², 2001

Machine-extracted title · confidence 31%

TEM analysis parameters and structure data for DOE sample.

NYC-WTC_000274182
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC ASSOCIATES INC. TEM ANALYSIS DAE GROUP #: - .LC:-I4 'C

Lab Sample Do. dALsA Filter Type MCE -I mm Operator

DlieilL Spl. No. 2C Filler Area 2S£ mm Instrument I.D. SE IC DRX id I.D. Disk No.

Screen Maqnificaoioo lc,'500X I GO) Area 0 . 01124 mm' Comments

Acc. Voltage SC kV No. GO to be Aiiaiyzed 3.147 Struct. Cor.spQ. to 70 s/mirPl.)

Structure structure Type Length I.D. of Structure EDS 7/0, (Nonasb. No Coord. No. >0.5 um iF B C M < 5 um >• Sum Chrys. Amphibole Nonasb. Ambig./ND Elements)

7.7' cl i/

V 4

i I . Photo No. (from 1 in 5 asbestos- Identify all structures using EDS Check diffraction for asbestos Store all unrepeated spectra containing samples) Grid acceptance:! structures up to 70a/i^m (1 st 4) <50% undissolvea filter, overlapped or folded Struct. = > 0.5um k > 5:1 Aspect Ratio <10% particulate coverage >50% coverage N= flot Obsei'vcd (EDS spectrum or diffraction pattern) at least 20 unfolded or overlapped grid squares Totals <5X holes or opaque areas Positive diffraction pattern properties conforming E B C M > Sum b) laboratory identification criteria observed. Unuaed portion Por chrysotile: 0.73nm spacing for (020) reflections. Of niter Chrysotile O.SSnm spacing for the layer line repeat, streaking 'Avoided pardon of (110) and (130) reflecUons. of niter For amphiboles: O.bOnm layer line repeat, and approx. portion of filter (2mm wide) 3.5 ratio of non-twtnned layer line spot spacing to subject to examination Amphibole layer line repeat distance (Q.53nm). EDS spectrum eonrorminf to laboratory Ambiguous identification criteria observed, AMPHIBOLES F= Sinfle Fiber (1-3 Intersections s 1-3 fibers) Amosite B= Bundle (>3 fibers <1 fiber diameter apart) C= Cluster (>3 intersections) ZSmrn fUtar I* Stopping Rules: L Crocidolite Non-asbestos M- Matrix T Anthophyllite NSD= No Structures Detected • >S0 i/C.O. or In l»t 4 C.O. Tremolite Actinolite Non-Identified i L;\DATA\PRIVATr\KIKBC\CADD\rEMa 9/22/90

CITY_21MC100_003107287

NYC-WTC_000274182

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274182Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000274127

TEM analysis run for lab group 5746; includes EM 10 CRX, EDS, and data.

Similar indexed content

Compare copies and versions →