TEM asbestos analysis; New Stuyvesant HS, sample 5758-62151, received 10/24/01.

NYC-WTC_000274162
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/25/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Tiber Identificaticn by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive »RAY Spectroscopy (EDS) Method: AIIERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. £2, No. 210, October 30, 1987

Sample Identification Ana2A^sj^s PaTarriet^r^

Pro^ect/Site: New Stu^^esant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5758 - 62151 Exterior a Interior of Buildinq & Roof Date Received Grid Openings Analyzed:__4

Project Sc.mple No. :_15 Average Grid Opening: 106.00 um

Air Volume : 1944 1J^ers Total Area /Analyzed: 0.0450 mm2

Filter Tyf • e: MCE 25 mtn diair.. Pore Size: 0.45 urn Analytical Sensitivity :22;J s/mm2 Effective Area: 3 8 5 mTn2 C■0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/'mm2 Struct/cc nqm/m3

Chrysotile Asbestos U 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes amoiguous structures) 0 0 0,0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0,0 0 . 0000 •N/A No Identification 0 0 c 0 0 0 0.0 0.0000 K/A

Totals (Ail Structures) 0 0 0.0 0.0000 N7A The estimc.ted uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Ane.lyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003107261

NYC-WTC_000274162

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274162Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000248381

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000293864

TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.

Similar indexed content

NYC-WTC_000293859

Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.

Similar indexed content

NYC-WTC_000274164

TEM asbestos analysis; New Stuyvesant HS, sample 5758-62154, received 10/24/01.

Similar indexed content

NYC-WTC_000292756

TEM report with sample 5785, exterior/interior details, for New Stuyvesant H.S., 10/28/01.

Similar indexed content

Compare copies and versions →