NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Asbestos TEM fiber analysis, New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 42%

TEM asbestos analysis; New Stuyvesant HS, received 10/24/03, sample 5758-62149.

NYC-WTC_000274160
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Flaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/25/01

ASBESTOS FIBER F.JIALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification .-?y Selected-Area Electron Diffraction iSAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AIERA Final Rule, I PA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 3C, 1987

Sample IdejitLfication Analysis Parameters

Pro3ect/Site: New Stuyvesant H.S., 34 5 Chambers St., NY, NY TEM Sample No.: 5758 62149 Exterior & Interior of Building & Roof Date Received: 10/24/03 Grid Openings Analyzed:__ 4

Project Sample No.: 13 Average Grid Opening: 106,. 00 um

Air Volumt?: 1944 liters Total Area Analyzed: C.0450 mm2

F.L1 cer Tyj)e: MCE 25 mm diam., Pore Size: 0.45 um Tina lytical Sensitivity :22^^s/mm2 Effective Area: 385 mm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers bundles Clusters Struct. Struct > = 5um Struct /mrr.2 Struct/cc ncrrn/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.9000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0,0 0.0000 0 Non-Asbestos 0 0 C 0 0 0 0.0 0.0090 N/A No Identification 0 0 C 0 0 0 C.0 0.0090 N/A

Totals (All Structures) 0 0 0.0 0.0090 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Ane.lyzed by; Report Reviewed by;

Ronan Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003107259

NYC-WTC_000274160

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274160Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270546

TEM asbestos analysis using SAED; project/site New Stuyvesant H.S.; includes date.

Similar indexed content

NYC-WTC_000270921

TEM asbestos analysis with diffraction/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000292759

TEM asbestos analysis with SAED and EDS parameters for New Stuyvesant High School, received 10/28/01.

Similar indexed content

NYC-WTC_000293677

TEM-based asbestos fiber analysis with SAED/EDS methods for New Stuyvesant High School samples.

Similar indexed content

NYC-WTC_000188707

Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.

Similar indexed content

Compare copies and versions →