ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/24/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, E:P7i Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification AnalysisParamete^

Project/Site-. Nev^ Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No. : Exterior & Interior of Building Sc Roof Date .received: 10/23/01 Grid Openings Analyzed:__4

Project Scimple Nc. : 10 Average Grid Opening: 106.QO um

Air Vclume; 1936 liters Total Area Analyzed: 0.0450 mm2

Filter Tyj>e: MCE 25 mm diam^ Pore Size: 0.45 urn Analytical Sensitivity;22;J s2mm2 Effective Area: 385 mm2 0■0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/'mm2 Struct/cc nqmZm3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0

Ambiguous I) 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes amoiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 C 0 0 0 0.0 0 . 0000 N/A No Identification 0 0 c 0 0 0 0.0 0 . 0000 K/A

Totals (All Structures) 0 0 0.0 0.0000 N’/A The estimated uncertainty cf this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003107208

NYC-WTC_000274116

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274116Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293864

TEM asbestos analysis for exterior/interior of building; includes opening and area measurements; received 10/23/01.

Similar indexed content

NYC-WTC_000188709

Technical report presenting transmission electron microscopy data for asbestos fiber identification on mixed interior and exterior samples.

Similar indexed content

NYC-WTC_000270680

TEM analysis of asbestos fibers; SAED/EDS identification, New Stuyvesant H.S., Oct 2001.

Similar indexed content

Compare copies and versions →