Asbestos TEM analysis, New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 41%

TEM-based asbestos identification and diffraction/EDS for New Stuyvesant High School, Oct 2001.

NYC-WTC_000274111
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/24/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification py Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, NPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 3C, 1987

Sample ide-.atification Analysis Parameters

Project/Si:e: New Stuyvesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5748 - 62Q58 Exterior & Interior of Building & Roof Date Received: 10/25/01 Grid Openings Analyzed:__4

Project Sample No.: 4 Average Grid Opening: 106.00 urn

Air Volumti Total Area Analyzed: 0.0450 mm2

Filter Ty} > e: MCE 25 mm diani., Pore Size: 0.45 urn Analytical Sensitivity :22^2 s/mrr^ Effective Ares: 385 mm2 0 . 0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/'mm2 StrucC/cc nam/m3

Chrysotile: Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbesto.s (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identif ication 0 0 0 0 0 c 0.0 0 . 0000 N'/A

Total,s (All Structures; 0 0 0.0 0.0000 N/A The estimeited uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Znalysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Anc.lyzed by: Report Reviewed by.

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003107202

NYC-WTC_000274111

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000274111Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000248385

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000274117

TEM asbestos analysis for New Stuyvesant High School, Oct 2001.

Similar indexed content

NYC-WTC_000244726

TEM SAED/EDS analysis; exterior/interior of building; sample 5737, received 10/21/01.

Similar indexed content

NYC-WTC_000248381

TEM asbestos analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

Compare copies and versions →