NYC-WTC_000244414
TEM TEM analysis results for New Stuyvesant High School exterior and interior; received 10/11/01.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗TEM analysis report for air samples at Stuyvesant High School, exterior and interior, Oct 2001.
NYC-WTC_000274105
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
104 East 25th Street New York, New York 10010 www.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.
October 24, 2001
N.y.C. Board of Education 28-11 Queens Plaza North 19125-0246 Long Island City, NY 11101 Attn: Mr. Bernard Orlan Re: Report of TEM Analysis
Clear Mr. Crlan:
Following are the results of transmission electron microscopy (TEM) analysis cf air samples from our Group No. 5748:
Project Name: New Stuyvesant H.S., 345 Chambers Street, NY, NY Location: Exterior and Interior of Building and Roof Samples received: 10/23/01
These results will confirm and document the data transmitted today to Mr. Andreas Andreau, Project Manager, of our office. The analyses were performed in strict conformance with the methodology of the AHERA Final Rule (40 CFR Part 763, Appendix A to Subpart E, October 30, 1987) for clearance of abatement sites. As indicated on the attached Summary Results sheet, no asbestos structures were detected in any of the twenty-one interior/exterior ambient samples submitted from the site.
Copies of the bench sheets are also included as stipulated by AHERA. MMI TEM cassettes. Lot No. 98307617, were used. Results reported as Struct/cc are a function of air volume collected in the field and are, as such, not verifiable by this laboratory. This report may be reproduced only in its entirety and not without prior permission of, this laboratory. If post-abatement inside samples pass, the response action may be considered to have been completed. The analyses were supervised by Dr. Michael A. Gorycki, Director of Electron Microscopy.
We are pleased to note that our TEM lab has received bull accreditation from NVLAP, as is currently required for recognized analysis of TEM air samples for AHERA projects, and also approval under the NY State DOH ELAP program. These analyses were performed by ATC d/b/a ATC Associates Inc. Please contact me regarding any questions relating to these materials.
Very truly yours,
Michael A. Gorycki, Ph.D. Director cf Electron Microscopy
CITY_21MC100_003107196
NYC-WTC_000274105
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000244414
TEM TEM analysis results for New Stuyvesant High School exterior and interior; received 10/11/01.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302851
TEM analysis results for Stuyvesant HS air samples 5785 (exterior/interior).
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182584
Cover letter and results for transmission electron microscopy analysis of air samples from a high school on October 23, 2001.
6 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294202
TEM analysis results for air samples at New Stuyvesant High School, AHERA methodology.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293933
TEM results and methodology for asbestos analysis per AHERA for NYC Board of Ed, Oct 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294167
TEM analysis results for New Stuyvesant High School air samples, Nov 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294159
TEM asbestos analysis results for Stuyvesant High School air samples, Nov 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273726
TEM asbestos analysis results for building samples at New Stuyvesant H.S., Nov 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000271719
TEM analysis results for air samples at New Stuyvesant High School, Nov 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273757
TEM analysis results for exterior/interior samples at New Stuyvesant H.S., Nov 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273797
TEM asbestos analysis report for Stuyvesant High School, 11/27/01.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294177
TEM asbestos analysis results for New Stuyvesant High School exterior/interior samples, Nov 2001.
6 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000244414
TEM TEM analysis results for New Stuyvesant High School exterior and interior; received 10/11/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302851
TEM analysis results for Stuyvesant HS air samples 5785 (exterior/interior).
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182584
Cover letter and results for transmission electron microscopy analysis of air samples from a high school on October 23, 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294202
TEM analysis results for air samples at New Stuyvesant High School, AHERA methodology.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000293933
TEM results and methodology for asbestos analysis per AHERA for NYC Board of Ed, Oct 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294167
TEM analysis results for New Stuyvesant High School air samples, Nov 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM TEM analysis results for New Stuyvesant High School exterior and interior; received 10/11/01.
Similar indexed content
NYC-WTC_000302851
TEM analysis results for Stuyvesant HS air samples 5785 (exterior/interior).
Similar indexed content
NYC-WTC_000182584
Cover letter and results for transmission electron microscopy analysis of air samples from a high school on October 23, 2001.
Similar indexed content
TEM analysis results for air samples at New Stuyvesant High School, AHERA methodology.
Similar indexed content
TEM results and methodology for asbestos analysis per AHERA for NYC Board of Ed, Oct 2001.
Similar indexed content