NYC-WTC_000378830
TEM results for air samples at New Stuyvesant High School, exterior/interior, received 12/22/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗ATC TEM-based asbestos analysis report for 5974 project, 11/26/01.
NYC-WTC_000273792–000273794OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Associates 104 East 25 Street, New York, NY 10010 Phone: (212). 353-8280 Fax:(212) 353-8306
Attn: Mr. Bernard Orlan Received: 11/25/01 6:00:00 PM N.Y.C. Board of Education 28-11 Queens Plaza North ATC Group #: 5974 Long Island City, NY 11101 Analysis Date: 11/26/01 Fax: (212) 475-4122 Phone: (212) 477-8941 Project: New Stuyvesant H. S. , 345 Chambers St., NY , NY Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHIRA) Analytical Asbestos Area Non Asbestos Structures Sensitivity Concentration Sample t^olume Analyzed Asb Type(s) 0.5u-5 5fi (S/cc) fS/mm-) (S/cc) Notes 1 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5974 -1
1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5974 -2
J 1944.00 0,0450 0 None Detected 0 0 0.0044 ;4 <0.0044 5974 -3
4 1952.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5974 -4
5 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5974 -5
6 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5974 -6
1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5974 -7
8 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5974 -8
MICHAEL A. GORYCKI, Ph.D. MARK PEYSAKHOV Analyzed by:
DiscJaimer: The laboratory is not responsible for data reported in struclures/cc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data reported in structures/mmT This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLMZTEM #101187-0, NY State ELAP #10879
CITY_21MC100_003106723
NYC-WTC_000273792
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000378830
TEM results for air samples at New Stuyvesant High School, exterior/interior, received 12/22/01.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000378859
TEM analytical data for air samples at New Stuyvesant High School; includes sample 1 details.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380647
TEM asbestos analysis results for air samples collected at the site.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398728
TEM asbestos analysis of exterior/interior air at New Stuyvesant HS, Dec 17, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000399026
Asbestos fiber TEM analysis report for exterior/interior building samples, AHERA method.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273218
TEM asbestos analysis results for exterior/interior areas at New Stuyvesant High School.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380070
TEM asbestos analysis of exterior and interior building air samples at New Stuyvesant High School, Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398852
Lab TEM asbestos analysis results with sample details for DOE project.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000378447
Chain-of-custody for TEM samples from New Stuyvesant H.S., Dec 8, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398763
TEM fiber analysis performed under AHERA for New Stuyvesant High School, Dec 2001.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379888
Chain-of-custody for AHERA TEM air samples.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000410774
TEM analysis results for air samples at New Stuyvesant High School, 01/30/02.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000294216
TEM microscopy results; exterior/interior building samples.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380469
TEM asbestos analysis with lab results and AHERA methodology notes.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000378314
AHERA TEM analysis results for exterior/interior samples at New Stuyvesant H.S., Jan 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273727
TEM analysis results for exterior/interior of building at New Stuyvesant H.S., Nov 2001.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000378830
TEM results for air samples at New Stuyvesant High School, exterior/interior, received 12/22/01.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000378111
Chain-of-custody for AHERA TEM asbestos analysis, New Stuyvesant H.S., Jan 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM results for air samples at New Stuyvesant High School, exterior/interior, received 12/22/01.
Similar indexed content
TEM analytical data for air samples at New Stuyvesant High School; includes sample 1 details.
Similar indexed content
NYC-WTC_000380647
TEM asbestos analysis results for air samples collected at the site.
Similar indexed content
TEM asbestos analysis of exterior/interior air at New Stuyvesant HS, Dec 17, 2001.
Similar indexed content
NYC-WTC_000399026
Asbestos fiber TEM analysis report for exterior/interior building samples, AHERA method.
Similar indexed content