NYC-WTC_000294286
TEM analysis results for air samples at New Stuyvesant High School exterior/interior.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗ATC TEM/AHERA analysis showing asbestos metrics for building samples.
NYC-WTC_000273581–000273583OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
ATC Associates 104 East 25 Street, New York, NY' 10010 Phone: (212) 353-8280 Fax: (212) 353-8306
Attn: Mr. Bernard Orlan Received: 11/5/01 8:15:00 PM N.Y.C. Board of Education 28-11 Queens Plaza North ATC Group#: 5838
Long Island City, NY 11101 Analysis Date: 11/6/01 Fax: (212)475-4122 Phone: (212) 477-8941
Project: New Stuyvesant H. S. , 345 Chambers St., NY', NY Exterior and Interior of Building and Roof
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHEBLA) Analytical Asbestos Area Non >isbestos Structures Sensitivi^' Concentration Sample Colume Analyzed Asb Type(s) 0.5fi-5 5/, (S/cc) (S/mm^) (S/cc) Notes 1 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5838 -1
1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5 S3 8 -2
3 None Detected 0 0 0.0044 <22.24 <0.0044 1944.00 0.0450 0 5838 -3
4 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5S3S -4
5 1944.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5838 -5
6 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5838 -6
7 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5838 -7
8 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 5838 -8
MICHAEL A. GORYCKI, Ph.D. ROMAN PEY3AKHOV
Analyzed by: Approved by: 4^
Disclaimer: The laboratory is not -esponsible for data reported in structureslcc, which is dependent on volume collected by non-laboratory personnel. This lab is only responsible for data reported in structures/mmr This report may not be reproduced, except in full, without written approval by ATC Associates Inc, This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S Government. This reports relates only to the samples reported above. Quality control date (including 95% confidence limits and laboratory and analysis' accuracy and precision; is available upon request.
Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879
CITY_21MC100_003106168
NYC-WTC_000273581
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000294286
TEM analysis results for air samples at New Stuyvesant High School exterior/interior.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398774
Asbestos TEM analysis of air samples for New Stuyvesant High School, Dec 24, 2001.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398863
TEM asbestos data sheet with sample volumes and IDs for DOE project.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000256806
TEM analysis results for exterior/interior of building; asbestos analysis per AHERA.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000294216
TEM microscopy results; exterior/interior building samples.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273589
AHERA TEM results detailing asbestos concentrations from building samples.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398959
TEM asbestos analysis of air samples from New Stuyvesant High School exterior/interior, Jan 2002.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379599
AHERA TEM analysis for exterior/interior building air samples; date 2/3/02.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000378772
TEM microscopy results for air samples at New Stuyvesant High School, exterior/interior, AHERA methodology.
7 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379315
TEM asbestos analysis results for 6293, New Stuyvesant HS, Jan 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379983
TEM asbestos analysis results for New Stuyvesant H.S., Feb 2002.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380647
TEM asbestos analysis results for air samples collected at the site.
7 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000271519
TEM asbestos analysis results for exterior/interior building areas at New Stuyvesant HS.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000398774
Asbestos TEM analysis of air samples for New Stuyvesant High School, Dec 24, 2001.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000380715
TEM analysis results for exterior/interior air samples at New Stuyvesant High School.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000261735
TEM analysis results for air samples at New Stuyvesant High School, exterior/interior, Feb 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000273189
TEM asbestos fiber analysis results for New Stuyvesant High School samples.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000379656
TEM fiber analysis for AHERA at New Stuyvesant High School building exterior/interior, Feb 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
TEM analysis results for air samples at New Stuyvesant High School exterior/interior.
Similar indexed content
Asbestos TEM analysis of air samples for New Stuyvesant High School, Dec 24, 2001.
Similar indexed content
NYC-WTC_000398863
TEM asbestos data sheet with sample volumes and IDs for DOE project.
Similar indexed content
TEM analysis results for exterior/interior of building; asbestos analysis per AHERA.
Similar indexed content
TEM microscopy results; exterior/interior building samples.
Similar indexed content