NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

TEM asbestos analysis, New Stuyvesant HS, Jun 2002

Machine-extracted title · confidence 59%

Asbestos TEM analysis report for New Stuyvesant High School samples.

NYC-WTC_000273394–000273396
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Associates 104 East 25 Street, New York, NY 10010 Phone; (212) 353-8280 Fax;(212) 353-8306

Attn: Mr. Bernard Orlan Received: 6/11/02 7:00:00 PM N.Y.C. Board of Education ATC Group#: 8051 28-11 Queens Plaza North Analysis Date: 6/11/02 Long Island City, NY 11101 Fax: (212)475-4122 Phone: (212)477-8941 Project: New Stuyvesant H. S., 345 Chambers St., NY , NY

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Non Asbestos # Structures Sensitivity Concentration Sample Volume Analyzed Asb Typeis) 0.5p-S S/t (S/cc) (S/mm^) (S/cc) Notes

1 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 < 0.0045 805/ -/

2 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 < 0.0045 805/ -2

3 . 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 8051 -3

4 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 S031 -4

5 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 305/ -5

6 1920.00 0.0450 0 None Detected 0 0 0.0045 <22.24 <0.0045 8051 -6

7 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044 805/ -7

MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.

Analyzed by: proved by

______ _______________________________________________ . Disclaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume colledted by non-laboratory personnel. This lab-iSonly responsible for data reported in structures/mmL This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples repotted above. Quality control data (including 95% confidence limits and laboratory and analysis’ accuracy and precision) is available upon request.

Accredited for NVLAP PLMfTEM #101187-0, NY State ELAP #10879

Page 1 of 3

CITY_21MC100_003105560

NYC-WTC_000273394

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000273394Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000298624

Asbestos fiber TEM analysis report for New Stuyvesant High School, 2002 AHERA.

Similar indexed content

NYC-WTC_000300024

Asbestos fiber TEM analysis data for exterior/interior areas of the building, Apr 2002.

Similar indexed content

Compare copies and versions →