December 10, 2001
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Board of Education ,
28-11 Queens Plaza North
Long Island City, NY 11101
Re: Air Sampling for Silica
Stuyvesant High School
ATC Project No. 15-19125-0246
Dear Mr. Orlan:
ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for silica-
containing dust conducted on November 15-16, 21 and 27, 2001, at the referenced school. The
New York City Board of Education (BOE) requested this sampling at the recommendation of H.
A. Bader, a consultant to the parents’ association.
ATC collected a total of thirty-six (36) samples (12 per session) for respirable dust using pre
weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-
respirable) particles prior to deposition on the filters. Six (6) samples were collected on
November 15* and six were collected on November 16*. Twelve samples were collected on
November 20* and 27*. Four (4) outdoor samples and thirty-two (32) indoor samples were
collected. The samples were sent to PSC Analytical Services, Inc., an American Industrial
Hygiene Association accredited laboratory in Reading, PA. Four blank filters were also
submitted. Analysis was performed by x-ray diffraction according to OSHA Method 142. A
copy of the analytical report is attached.
Silica was found above the limits of detection in only one of the thirty-six samples. This was the
sample (#ATC-11I5-STY-S4) collected on November 15* in Room 635. This sample contained
0.023 milligrams of silica per cubic meter of air (mg/m^). The Occupational Safety and Health
Administration (OSHA) Permissible Exposure Limit (PEL) for silica-containing dust is based on
the percent of quartz (SiOf) found in the dust, the higher the percentage of quartz, the' lower the
PEL. The formula for calculating the PEL is found in 29 CFR 1910.1000, Table Z-3. The
fonnula is: 1 Omg/m^
%SiO2 + 2
The amount of quartz in Sample #ATC-1115-STY~S4 was 18%, therefore the PEL for this dust
would be:
10mg/m~^ = 0.50 mg/m^
18 + 2
The silica concentration in this sample was 0.023 mg/mg\ which is 4.6% of the calculated PEL.
CITY_21MC100_003101377
NYC-WTC_000272055