Lead monitoring, Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 42%

Limited area airborne lead sampling at Stuyvesant HS, Oct 2001.

NYC-WTC_000271982–000271985
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

A low-volume, personal sampling pump was utilized for the collection of air samples. This is the same type of apparatus used to gather personal exposure data. The sampling pumps were placed in areas indicated to ATC by a NYC-BOE representative on site.

Tubing was connected to the sampling pump. A three-piece filter cassette was attached to the terminus end of the tubing. The filter used for the monitoring was a 0.37 pm mixed cellulose ester membrane.

At the beginning of the sampling period the plug on the inlet of the cassette is removed and the pump is started. The face of the cassette is not removed, as is done for asbestos sampling. The sampling pump is checked for calibration at the beginning and the end of each sampling period using a calibrated rotometer. The time the pump is started and tumed-off is noted on field forms.

The pump was checked periodically for satisfactory during the sampling period. At the end of the sampling period the air flow was checked with the rotameter and the cassette was removed and submitted to a laboratory for analysis. Proper chain of custody records were maintained for each sampled collected.

Results of area air monitoring A total of five (5) area air samples were collected and analyzed for lead content. In addition, two “blank” samples were collected to determine that the cassettes were free of lead particles and the handling of the samples by ATC did not contribute additional lead to the samples.

Analytical results indicated that all collected area air samples were below the “Action Level” for airborne lead of 30 pg/m’ (micrograms per cubic meter).

Please refer to Appendix A for a comprehensive lab report and chain of custody records from the limited area air sampling performed at Stuyvesant HS (M477).

Limits of the limited area air sampling Area air monitoring was conducted at the NYC-BOE request and a NYC-BOE representative indicated the sampling locations to ATC. NYC-BOE was infonned that there is not an existing protocol for area monitoring and that ATC would use the methodology established for OSHA personal samples. The results of this report are applicable for the time that testing was performed. If questions arise concerning lead content in or on components not tested by ATC, then additional testing services should be procured. ATC makes no representation or warranty concerning the standards and specifications provided in the HUD Guidelines and the NYC BOE protocol.

Stuyvesani HS (M477) October 22, 2007

CITY_21MC100_003101227

NYC-WTC_000271984

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000271984Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →