TEM asbestos analysis, New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 58%

TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.

NYC-WTC_000270968
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza-North ACCREDITED NVLAP Lab Code # 1187 ■ Long Island City, NY 11101 . Report Date; 10/29/01

ASBESTOS FIBER ANTkLYSIS BY TRjVNSMISSIQN ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Pinal Rule, SPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuwesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5785 - 62418 Exterior & Interior of Building & Roof Date Received: 10/28/01 Grid Openings Analyzed:__ 4

Project Sample No.: 9 Average Grid Opening: 106.00 urn

Air Volume : 1928 Uters Total Area Analyzed: 0.0450 mni2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity:22;2 s2mrn2 Effective Area: 385 mm2 0,0044 s/cc

FIBROUS PARTICULATES j\NALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter ' Air Fibers Bundles Clusters Struct. Struct >=5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED); None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC1OO_OO3O99937

NYC-WTC_000270968

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270968Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000293860

Asbestos TEM analysis parameters for New Stuyvesant HS exterior/interior; Oct 2001.

Similar indexed content

NYC-WTC_000270678

TEM analysis with SAED/EDS for New Stuyvesant H.S., Oct 2001.

Similar indexed content

NYC-WTC_000270379

TEM asbestos analysis report for exterior/interior of building, Oct 2001.

Similar indexed content

NYC-WTC_000270978

TEM asbestos analysis for New Stuyvesant High School site, received 10/28/01.

Similar indexed content

NYC-WTC_000270545

TEM asbestos analysis with AHERA method for New Stuyvesant H.S.; lists sample numbers and date.

Similar indexed content

Compare copies and versions →