ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N'.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code #-1187 ' Long Island City, NY 11101 Report Date10/29/01

ASBESTOS FIBER ANALYSTS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS} Method; AHERA Final Rule, EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification Analysis Parameters

Project/Site: New Stuyvesant H.S., 34 5 Chambers St., NY, NY TEM Sample No.: 5765 - 62414 Exterior & Interior of Building & Roof Date Received: 10/28/01 Grid Openings Analyzed;__ 4

Project Sample No.: 5 Average Grid Opening: 106.00 um

Air Volume: 1920 liters Total Area Analyzed: 0.0450 mm2

Filter Type: MCE 25 mm diam.. Pore Size; 0.45 um Analytical Sensitivity:22:2 s/mm2 Effective Area: 385 mm2 0.0045 s/cc

FIBROUS PT^TICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 • 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures} 0 0 0.0 0.0000 ' o' Non-Asbestos 0 0 0 0 0 0 0.0 O.DOOO N/A No Identification 0 0 0 0 0 0- 0.0 -0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type; None detected

The Tinalysis was carried out in'accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed-by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITy_21MC100_003099933

NYC-WTC_000270964

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270964Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270974

TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.

Similar indexed content

NYC-WTC_000270590

TEM asbestos identification using SAED/EDS for air samples at New Stuyvesant High School site.

Similar indexed content

NYC-WTC_000270705

TEM analysis report for New Stuyvesant HS with TEM/SAED/EDS results.

Similar indexed content

NYC-WTC_000270800

TEM asbestos analysis for New Stuyvesant High School exterior/interior, received 10/24/01.

Similar indexed content

NYC-WTC_000270809

TEM asbestos analysis, New Stuyvesant High School exterior/interior, received 10/24/01.

Similar indexed content

Compare copies and versions →