NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM asbestos analysis, New Stuyvesant HS, Oct 2001

Machine-extracted title · confidence 58%

TEM asbestos analysis with SAED/EDS for New Stuyvesant HS exterior/interior, Oct 2001.

NYC-WTC_000270962
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York^ 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code. #’ 118 7 Long Island City, NY 11101 Report Date: 10/29/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule, EPA Federal Register (40 CPR, Part 763), Vol. 52, No; 210, October 30, 1987

Sample IdentificaLion Analysis Parameters

Project/Site; New Stuyyesant H.S., 345 Chambers St., NY, NY TEM Sample No.: 5785 - 62412 Exterior & Interior of Building & Roof Date Received: 10/28/01 Grid Openings Analyzed:__ 4

Project Sample No. Average Grid Opening: 106.00 urn

A.Lr Volume: 1936 liters Total Area Analyzed: 0.045Q mm2

Filter Type: MCE 25 mm diam. Pore Size: 0.45 um Analytical Sensitivity:.^22;.2 s/mm2 Effective Area: 385 mm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct >g5um Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 . 0 0 0 0 0 •0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0 . 0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_0 03099931

NYC-WTC_000270962

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270962Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270977

TEM-based asbestos fiber analysis with SAED/EDS for New Stuyvesant High School, received 10/28/01.

Similar indexed content

NYC-WTC_000293901

TEM data with air volume and analysis parameters for building sample.

Similar indexed content

NYC-WTC_000292757

TEM analysis notes: exterior/interior of building and data parameters for 10/28/01.

Similar indexed content

NYC-WTC_000270670

TEM analysis of asbestos fibers at New Stuyvesant H.S. with SAED/EDS, Oct 2001.

Similar indexed content

NYC-WTC_000292752

TEM analysis with air volume and opening details for exterior/interior of New Stuyvesant H.S., 10/28/01.

Similar indexed content

Compare copies and versions →