ATC ASSOCIATES INC. TEM ANALYSIS LAB GROUP #: 57B4 - 10/27/01 Lab Sample No. 62391 Filter Type MCE 25 mm Operacor Client Spl. No. 6 Filter Area 385 mm'2 Instrument I.D. EM 10 CRX Screen Maanificacion 16.400X Grid I.D. (GO) Area —w_ 0.01124 mm"2 Disk No. Commencs Acc. Voltage 60 kV No. GO to be Analyzed __4 I 3'. 147 Struct. Corspd. to 70 G/mm,"2.)

Length I.D. of Structure EDS GO. Structure Structure Type (Nonasb. No. Coord. No. . F B C M ^0.5 um < 5 um Sum Chrys. Amphibole Nonasb. Ambig./ND Elements] / t/ fl /(

Photo No. (from 1 In 5 asbestos- Identify all structures using EDS Chee c diffraction for asbealos store all unrepeated apectra containing samples) Grid acceptance:! atrucLurea up to TOa/i^m (l»t 4) Struct. = > O.Sum & > 5:1 Aspect Ratio <50X undiaaolvea filter, overlapped or folded" <10X particulate coverage >S0X coverage Totals Ns Not Observed (EDS spectrum or diffraction pattern) at least 20 unfolded or overlapped grid squares Positive diffraction pattern properties conforming <SX holes or opaque areas F B C M > Sum to laboratory identification criteria observed. •Unuasd portion For chryaoUle; 0.73nm spacing for (020) reflections. of filter Chrysotile O.sanm spacing for the layer line repeat, atreaklng ‘Avoided portion of (110) and (130) reflections. of filter For amphiboles: O.S3nm layer line repeat, and approx. Portion of filter (2inin wide) 3.5 ratio of non-tvinned layer line spot spacing to subject to •xamlnatleo Amphibole layer line repeat distance (Q.SOnm). EDS spectrum conforming to laboratory Ambiguous identification criteria observed. AMPHIBOLES ps single Fiber (1-3 Intersections s 1-3 fibers) Amosite B« Bundle (>3 fibers <1 fiber diameter apart) 25mm flltar Crocidolite Non-asbestos C= Cluster (>3 Intersections) , I'* stopping Rules; I , Anthophyllite Ms Matrix NSD= No Structures Detected >50 i/C.o. or in isi 4 G.O. Tremolite Actinolite Non-Identified L\OATA\PRiVATB\MlKEC\CADDVEMa . 0/22/88

CITY_21MC1OO_OO3O999O6

NYC-WTC_000270938

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270938Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →