TEM ASBESTOS ANALYSIS, New Stuyvesant H.S., Oct 2001

Machine-extracted title · confidence 43%

TEM analysis of asbestos fibers for exterior/interior of building, Oct 2001.

NYC-WTC_000270925
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

N.Y.C. Board of Education Approved N.Y. State ELAP #10879 28-11 Queens Plaza North ACCREDITED NVLAP Lab Code # 1187 Long Island City, NY 11101 Report Date: 10/28/01 ,

ASBESTOS FIBER 7VNALYSI5 BY TRTkNSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS) Method: AHERA Final Rule. EPA Federal Register (40 CFR, Part 763), Vol. 52, No. 210, October 30, 1987

Sample Identification AnalysisParamete^

Project/Site: New Stuyvesant H.S, 345 Chambers St., NY, NY TEM Sample No.; 5784 62397 Exterior & Interior of Buildino & Roof Date Received: 10/27/01 Grid Openings Analyzed;__ 4

Project Sample No.: 12 Average'Grid Opening: 106.00 urn

Air Volume: 1936 liters Total Area Analyzed: 0.045C mm2

Filter Type; MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity :2r^2 s/m!n2. Effective Area; 385 mm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. • Struct. Filter Air Fibers Bundles Clusters Struct. Struct >c5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ambiguous 0 0 0 0 0 0 0.0 0.0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0.0000 N/A

Totals (All Structures) 0 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Roman Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003099891

NYC-WTC_000270925

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000270925Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000270877

TEM asbestos analysis; exterior/interior, sample 10.

Similar indexed content

NYC-WTC_000270754

Asbestos fiber analysis by TEM at New Stuyvesant High School exterior/interior; includes SAED/EDS identifications.

Similar indexed content

NYC-WTC_000293820

TEM analysis of exterior/interior building samples; SAED/EDS; Received 10/22/01.

Similar indexed content

Compare copies and versions →